Purpose

Electronic bistable pulse relay switch that turns on or off lights or 
other equipment from several different points with the parallel 
connected momentary (bell) control switches.
The relay has two independently controlled channels.

D141222/150119

Specifications

Wiring diagram

Operation

The relay is activated with a current pulse caused by the press of 
any momentary (bell) button connected to the relay. Subsequent 
pulse will switch the relay off. 
The relay has two independently controlled channels.
Control  is  carried  out  by  means  of  two  separate  signal  inputs.   
Pulse on  S1 input controls the R1 output. S2 input and R2 output 
operate on the same basis.
The relay does not have a "memory" of the contact position, i.e. 
when power returns after power failure, contact  of the relay will 
be set in the disabled state. This prevents automatic switching of 
controlled  receivers  without  supervision  after  prolonged  power 
outage.

BISTABLE RELAY

dual-channel

BIS-416

5

9 0 8 3 1 2

5 9 8 2 7 5

power supply

V AC

contact / AC-1 load current
control L pulse current

< mA

response delay

0.1÷0.2s

power indicator

green LED

power consumption
      standby

0.

W

      on

0.6W

working temperature

-

÷50°C

terminal

2.5mm  screw terminals

tightening torque

0.4Nm

mounting

in the Ø60 flush-mounted box

ingress protection

I 20

100÷265

2×1NO / 2×[<8A] 

5

15

25

²

dimensions

Ø

54 (□48×43mm), h=20mm

P

N

N

2

3

5

L

1

S2

L

6

4

PWR

N

L

S1

R2

R2

R1

R1

L

S1

S2

N

R1

R2

Installation

Note!

R1

R2

S1

S2

U

1000W

500W

600W

incandescent

fluoroscent

energy-saving

halogen

LED

250W

120W

Power table

The  above  data  are  indicative  and  will  heavily  depend  on  the 
design of a specific receiver (that is especially important for LED 
bulbs,  energy-saving  lamps,  electronic  transformers  and  pulse 
power  supply  units),  switching  frequency  and  operating 
conditions.
For more information visit

:

 www.fif.com.pl

F&F Filipowski sp. j.

Konstantynowska 79/81   95-200 Pabianice   

phone/fax: (+48 42) 215 23 83 / 227 09 71    POLAND

http://www.fif.com.pl   e-mail: [email protected]

Do not dispose of this device to a garbage bin with other unsorted waste! 

In  accordance  with  the  Waste  Electrical  and  Electronic  Equipment  Act 
any  household  electro-waste    can  be  turned  in  free  of  charge  and  in  any 
quantity to a collection point established for this purpose, as well as to the 
store in the event of purchasing new equipment (as per the old for new rule, 
regardless of brand). Electro-waste thrown in the garbage bin or abandoned 
in the

 

bosom of nature pose a threat to the environment and human health.

WARRANTY.

  The  F&F  products  are 

covered by a warranty of the 24 months   
from the date of purchase.  Effective only 
with  proof  of  purchase.  Contact  your 
dealeror  directly  with  us.  More 
information how to make a compliant can 
be found on the website:
www.fif.com.pl/reklamacje

1. Disconnect the power supply.
2. Mount relay in the flush-mounted box.
3. Connect the power supply cables to PWR group: phase wire L 

to terminal 4, neutral wire N to terminal 3.

4. Parallel connected S1 momentary switches (R1 section 

control) connect to terminal 2 and phase wire L. Parallel 
connected S2 momentary switches (R2 section control) 
connect to terminal 1 and phase wire L.

5. Powered receiver of section R1 connect in series to terminal 6 

and neutral wire N. Powered receiver of section R2 connect in 
series to terminal 5 and neutral wire N.

BIS-416 is compatible with backlit buttons.