Power connections
The user must select the output mode (Bridge or Stereo) for
the 4 power channels using the front display and navigation
keys or using the ALMA software.
Losses for 100/70V lines
These values serve as a reference when selecting cable gauge
/ length (copper cables) for maximum admissible distances
in high quality installations and maximum losses of up to 10%
(1dB):
For 70V lines, the distances above should be divided by 2.
For example, the maximum admissible distance for a 2mm2,
200W and 70V line would be 325/2=162.5meters.
Losses for 4/8ohm lines
These values serve as a reference for the most common cable
gauge /length (copper cables) for maximum admissible dis-
tances and maximum losses of up to 10% (1dB):