INSTALLING THE MICRO INVERTER
The following sections list steps on how to install the G320 micro inverter onto
standard PV racking.
Installing onto a PV Racking System
Step 1: Measure the AC Service at the Site
Measure service entrance conductors to
confirm AC service at the site. Verify the AC
voltages at the electrical utility connection and at the junction box for each AC
branch circuit are within the ranges.
Step 2: Install the AC Branch Circuit Junction Box
2.1.
Mount the adapter plate to a
suitable location on the PV
racking system (typically at the
end of a row of modules). The
adapter plate must be installed
with an appropriate junction
box.
2.2.
Connect the open wire end of the AC
interconnect cable into the junction
box using an appropriate gland or
strain relief fitting. The AC
interconnect cable requires a strain
relief connector with an opening of
3/8 inches in diameter.
Step 3: Lay Out the AC Trunk Cable
Place the AC trunk cable at the required location. Align the connector to the
position where the micro inverter will be installed. Then secure the cable on
either side of the rack using cable clips or tie wraps.
Note the G640 is the micro inverter of the input of two photovoltaic panels.
Please pay attention to fix the G640 in the middle of two photovoltaic modules
when wiring.
Step 4: Attach the Micro Inverter to the PV Racking
4.1.
Note the approximate centers of each PV module on the PV racking.
4.2.
Evaluate the location of the micro inverter against potential collection of
moisture or water.
4.3.
Evaluate the location of the micro inverter with respect to the DC junction
box and the PV module frame.
4.4.
Align the G640 so that the holes on the mounting bracket are above the slot
opening on the PV racking and secure the micro inverter to the PV racking
with screws.
CAUTION
Ensure that the inverter does not obstruct the PV module frame or
stiffening braces. Ensure the micro inverter’s AC connector can easily reach the
AC trunk cable.
Step 5: Ground the Micro Inverters
[Option 1]: Integrated Grounding. Go to step 6. No additional grounding is
needed.
[Option 2]: GEC Grounding. Unscrew the top of grounding clips on the micro
inverters. Run the grounding electrode conductor to each grounding clip on the
Wire Connection 240V (Single Phase)
L1 to L2
193 to 242VAC