Junction Box. The PLC Box will need to be placed in and secured to the AC
Junction Box. The wires in the AC trunk cable are identified by color
Step 3:
Connect the Data Logger to the Router
Place the data logger (model: DDL100 or DL200) near the router, then make
a direct Ethernet connection. If the data logger cannot be placed near the
router, then the installer can add either a wireless access port or a power
line communication port (not supplied with the micro inverter).
Note: To mount the data logger, use the included wall-mount frame.
Step 4:
Connect the Data Logger to the PLC Box
Insert the red/black wiring into the RS485 connectors, and then
insert the connectors into the Data Logger and PLC Box. (Ensure
there is length of the red/black wiring is sufficient for installation)
Note: Ensure the RS485 connectors are wired properly:
Data Logger RS485 D+
PLC Box RS485 T +
Data Logger RS485 D-
PLC Box RS485 T
–
Note: If installing more than one PLC Box in the system, daisy-chain the PLC
Boxes together using RS485 cables. Then connect the last PLC Box in the series to
the Data Logger using the RS485 cable.
Step 4: Connect Power
Plug in the Data Logger into the AC outlet. (Be sure the adapter is connected to
the Data Logger before it is plugged into to the outlet.)