IMPORTANT SAFETY INSTRUCTIONS
Safety Instructions
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING ANY PRODUCTS OR
DEVICES & KEEP FOR FUTURE REFERENCE.
This manual contains important instructions for the installation and maintenance
of G640 micro inverters. Before installing, please read these safety instructions
carefully. Take special care to follow the warnings indicated on the unit itself as
well as the safety instructions listed below.
Safety Symbols
To reduce the risk of injury and to ensure the continued safe operation of this
product, the following safety instructions and warnings are marked in this
manual.
WARNING
This indicates the risk of electric
shock. The presence of high
voltage levels may constitute a
risk of injury or death to users and/or installers.
CAUTION
This indicates important
information where failure to
comply may result in safety
hazards or cause damage to this product.
Safety Instructions
•
Read all instructions and cautionary marks in the manual carefully before
starting the installation.
•
Do not attempt to repair this product; it does not contain user-serviceable
parts. Repairs and internal servicing should only be performed by authorized
service personnel.
•
Do not tamper with or open this product. Opening this product may result in
electric shock.
•
Perform all electrical installations in accordance with all applicable local
electrical codes and the National Electrical Code (NEC), ANSI/NFPA 70.
•
Only qualified electrical personnel should perform the electrical installation and
wiring of this product.
•
Be aware that even without an external voltage source connected, the micro
inverter may contain high voltages and there is a risk of electrical shock.
•
Connect the micro inverter to the utility grid only after receiving prior approval
from the electrical utility company.
•
The temperature of the heat sinks outside of the device can reach over 85
°
C in
normal operation. To reduce risk of burns, use caution when working with
micro inverters.
•
Do not disconnect the DC power source from the micro inverter without first
disconnecting the AC power source. Both AC and DC power sources must be
disconnected before servicing. Be aware that DC power/voltage is generated
when the photovoltaic array is exposed to light.
•
Switch off the circuit breakers before installation and wirings.
•
For the safety of installation, remove all conductive jewelry or equipment
during the installation or service of the device parts, connector and/or wiring.
•
Do not stand on a wet location while doing installation and wirings. Enclose the
outer covering well before switch on the circuit breakers.
•
The micro inverters should be installed as instructed in this manual. Failure to
comply with these precautions or with specific warnings elsewhere in this
manual violates safety standards of design, manufacture, and intended use of
the device. The manufacturer assumes no liability for the customer’s failure to
comply with these requirements.
•
When a GFDI fault (Ground fault) occurs, the LED will flash in red light. Please
refer to the POST-INSTALLATION section for more introductions.
Surge Suppression
Lightning does not actually need to strike the equipment or building where the
PV system is installed to cause damage. Often, a strike nearby will induce voltage
spikes in the electrical grid that can damage equipment. Artificial spikes such as
those induced by electric motors starting up can also cause damages to the
equipment.
The micro inverters have integrated surge protection built-in; however, if the
surge has sufficient energy, the built-in protection in the device would be
exceeded and the device could potentially be damaged. Therefore, external surge
protection MUST be installed as part of any solar installation.
WARNING
When installing a surge protection device (SPD), one MUST follow the original
manufacturer’s instructions on how to install the SPD properly. Incorrect
installation of the SPD may still cause damages to the micro inverters. If the
installation site is known for unstable or heavy surges, then it is the
responsibility of the installer to make sure the SPD chosen can adequately
protect the micro inverters.