IMPORTANT SAFETY INSTRUCTIONS 

Safety Instructions 

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING ANY PRODUCTS OR 

DEVICES & KEEP FOR FUTURE REFERENCE. 

This manual contains important instructions for the installation and maintenance 

of G640 micro inverters. Before installing, please read these safety instructions 

carefully. Take special care to follow the warnings indicated on the unit itself as 

well as the safety instructions listed below. 

 

Safety Symbols 

To reduce the risk of injury and to ensure the continued safe operation of this 

product, the following safety instructions and warnings are marked in this 

manual. 

 

WARNING 

This indicates the risk of electric 

shock. The presence of high 

voltage levels may constitute a 

risk of injury or death to users and/or installers. 

CAUTION 

This indicates important 

information where failure to 

comply may result in safety 

hazards or cause damage to this product.

 

 

Safety Instructions 

 

Read all instructions and cautionary marks in the manual carefully before 

starting the installation. 

 

Do not attempt to repair this product; it does not contain user-serviceable 

parts. Repairs and internal servicing should only be performed by authorized 

service personnel. 

 

Do not tamper with or open this product. Opening this product may result in 

electric shock. 

 

Perform  all electrical installations in accordance with all applicable local 

electrical codes and the National Electrical Code (NEC), ANSI/NFPA 70. 

 

Only qualified electrical personnel should perform the electrical installation and 

wiring of this product. 

 

Be aware that even without an external voltage source connected, the micro 

inverter may contain high voltages and there is a risk of electrical shock. 

 

Connect the micro inverter to the utility grid only after receiving prior approval 

from the electrical utility company. 

 

The temperature of the heat sinks outside of the device can reach over 85

°

C in 

normal operation. To  reduce risk of burns, use caution when working with 

micro inverters. 

 

Do not disconnect the DC power source from the micro inverter without  first 

disconnecting the AC power source. Both AC and DC power sources must be 

disconnected before servicing. Be aware that DC power/voltage is generated 

when the photovoltaic array is exposed to light. 

 

Switch off the circuit breakers before installation and wirings. 

 

For the safety of installation, remove all conductive jewelry or equipment 

during the installation or service of the device parts, connector and/or wiring. 

 

Do not stand on a wet location while doing installation and wirings. Enclose the 

outer covering well before switch on the circuit breakers. 

 

The micro inverters should be installed as instructed in this manual. Failure to 

comply with these  precautions or with specific warnings elsewhere in this 

manual violates safety standards of design, manufacture, and intended use of 

the device. The manufacturer assumes no liability for the customer’s failure to 

comply with these requirements. 

 

When a GFDI fault (Ground fault) occurs, the LED will flash in red light. Please 

refer to the POST-INSTALLATION section for more introductions. 

Surge Suppression 

Lightning does not actually need to strike the equipment or building where the 

PV system is installed to cause damage. Often, a strike nearby will induce voltage 

spikes in the electrical grid that can damage equipment. Artificial spikes such as 

those induced by electric motors starting up can also cause damages to the 

equipment. 

 

The  micro inverters have integrated  surge protection  built-in; however, if the 

surge has sufficient  energy, the built-in protection in  the device would be 

exceeded and the device could potentially be damaged. Therefore, external surge 

protection MUST be installed as part of any solar installation.   

 

WARNING

 

 

When installing a surge protection device (SPD), one MUST follow the original 

manufacturer’s instructions on how to install the SPD properly. Incorrect 

installation of the SPD may still cause damages to the micro inverters. If the 

installation site is known for unstable or heavy surges, then it is the 

responsibility of the installer to make sure the SPD chosen can adequately 

protect the micro inverters. 

 

Содержание G640

Страница 1: ...G640 MI CRO I NVERTER U S E R M A N U A L...

Страница 2: ...OTECTION 7 INSTALLING THE MICRO INVERTER 8 INSTALLING ONTO A PV RACKING SYSTEM 8 POST INSTALLATION 10 COMMISSIONING AND OPERATING 10 GFDI FAULT 10 DISCONNECTING A MICRO INVERTER 10 MONITORING SYSTEM 1...

Страница 3: ...operation To reduce risk of burns use caution when working with micro inverters Do not disconnect the DC power source from the micro inverter without first disconnecting the AC power source Both AC an...

Страница 4: ...ogue pdf Citel MSB10 400 http www citel fr userfiles medias Datasheet fiche_anglaise MSB10 UL__A _F141103A pdf FCC Compliance This equipment has been tested and found to comply with the limits for a C...

Страница 5: ...e is recommended such as Belden 3105A however any twisted pair cable can be used such as CAT5 with some degradation of signal and distance Parts and Tools This section provides a list of equipment and...

Страница 6: ...o each G640 by completely isolating the internal DC circuit from the AC circuit and ground DC ground faults are detected on either the positive and or negative conductors of the DC circuit by a Ground...

Страница 7: ...ial number sticker on the DC side can be peeled off the micro inverter and adhered to the installation map template where the actual position on the roof would correspond to the same panel on the layo...

Страница 8: ...tion Align the connector to the position where the micro inverter will be installed Then secure the cable on either side of the rack using cable clips or tie wraps Note the G640 is the micro inverter...

Страница 9: ...as four parts the sealing nut clamp ring seal and cap Slide the sealing nut clamp ring and then the seal onto the AC trunk cable 7 3 Insert the individual wires into the slots inside the cap of the en...

Страница 10: ...allic enclosures metallic raceways metallic equipment or earth When a Ground fault occurs the GFDI will trigger the LED light to show continuous Red and the micro inverter will automatically disconnec...

Страница 11: ...the termination resistor switch on both the Data Logger and PLC Box should be switched ON If the distance between the Data Logger and PLC Box is less than 50m then the termination resistor switch on b...

Страница 12: ...connect the PV circuit from any grid power before installing the PLC box to the AC trunk cable or AC junction box Step 1 Connect the Data Logger to the Router There are two ways to connect the data lo...

Страница 13: ...he micro inverter Note To mount the data logger use the included wall mount frame Step 4 Connect the Data Logger to the PLC Box Insert the red black wiring into the RS485 connectors and then insert th...

Страница 14: ...Step1 Verify that any upstream AC disconnects as well as the dedicated circuit breakers for each AC circuit are functioning properly and are closed Step2 Verify that the AC voltages at the electrical...

Страница 15: ...rrectly use the steps below to troubleshoot the problem If the issue cannot be resolved using these steps please contact inverter maker s technical services Power LED did not turn on Verify that the P...

Страница 16: ...or local regulation PLC Box COMMUNICATION Serial Port Interface 1 x RS485 For Data Logger 1 Maximum Number of Devices Up to 24 Micro Inverters Maximum Transmission Distance2 Up to 164ft 50m MEMORY Int...

Страница 17: ...G 6 4 0 M i c r o I n v e r t e r U s e r M a n u a l G 6 4 0 U M d r a f t v1 20180928 2 0 1 8 D a r f o n E l e c t r o n i c s C o r p p 1 7 1 9 SAMPLE WIRING 240V 1...

Страница 18: ...C o r p p 1 8 1 9 INSTALLATION MAP TEMPLATE Use this map to draw the array and keep track of the micro inverters placement by serial number Peel off and use secondary serial number label on the micro...

Страница 19: ...d by Darfon Electronics Corp 167 Shan ying Road Gueishan Taoyuan 333 Taiwan R O C Tel 886 3 2508800 USA Office Darfon America Corp 103A Pioneer Way Mountain View CA 94041 Tel 1 650 316 6300 For more i...

Отзывы: