52
EN
RS-485 Interface
Continued
Register Byte
Database
parameter
Min
Max
De-
fault
Description
7
12
Evap_
temp2
(decimal)
-40
100
0
Temperature from evaporator 2:
Usage the same as above.
13
Evap_
temp2
(fraction)
-40
100
0
8
14
Cond_
temp1
(decimal)
-40
100
0
Temperature from condenser:
Usage the same as above.
15
Cond_
temp1
(fraction)
-40
100
0
9
16
Aux_temp
(decimal)
-40
100
0
Temperature from auxiliary sensor:
Usage the same as above.
17
Aux_temp
(fraction)
-40
100
0
10
18
Amb_temp
(decimal)
-40
100
0
Temperature of ambient air:
Usage the same as above.
19
Amb_temp
(fraction)
-40
100
0
11
20
Amb_hum
(High byte)
0
100
0
Humidity of ambient air:
High byte has no meaning and always contains zero.
Only low byte can be used.
21
12
22
RH_set
40
95
40
Setpoint value of desired humidity.
23
RH_Fan
40
95
40
Setpoint value of humidity for exhaust fan start.
13
24
Temp_set
(decimal)
0
36
0
Setpoint value of desired temperature:
Usage the same as for Evap_temp1.
25
Temp_set
(fraction)
16
30
Fail_start
0
1
0
State of Fail_start mode
31
SB_mode
0
1
0
Stand-by mode state
17
32
DEH_mode
0
1
0
Dehumidifying state
33
Ice_mode
0
1
0
Deicing state
Содержание CDP 50
Страница 9: ...9...
Страница 14: ...14 EN CDP 40 50 70 CDP 40T 50T 70T Dimensions...
Страница 18: ...18 EN CDP 40T 50T 70T Mounting and installation instructions CDP T 1...
Страница 19: ...19 EN Mounting and installation instructions CDP T Continued CDP 40T 2a CDP 50T 2b CDP 70T 2c...
Страница 20: ...20 EN 3 Mounting and installation instructions CDP T Continued...
Страница 35: ...35 EN Overview Accessories Water heating coil for CDP dehumidifier...
Страница 50: ...50 EN Spare parts 1 4 5 6 7 15 10 14 20 19 22 13 12 8 24 23 26 16 21 11 17 18 9 3 2 27 28 25...