page 7 of 10
Oilbuner
Type Gulliver RG3D
GB
Combustion adjustment:
To suit the required appliance output, fit the nozzle then adjust the pump pressure, and the
air damper opening in accordance with the following schedule.
Nozzles recommended:
Delavan:
Type W – B
Danfoss:
Type S – B
Monarch:
Type R
Steinen:
Type S – Q
K:\framen\instrukt\Dantherm\RG\Engelsk\RG3D\RG3.fm--021115-dm/lbk
Adjustment
Nozzle
Pumpetryk
[bar]
Burner output
[kg/h ± 4%]
combustion head
adjustment
Set-point
Airdamper
adjustment
[GPH]
Angle
1st stage 2nd stage 1st stage 2nd stage
1st stage 2nd stage
1,50
60°
9
15
5,3
6,8
0,0
0,2
0,5
1,75
60°
9
15
6,4
8,2
0,5
0,25
1,0
2,00
60°
9
15
7,2
9,3
1,5
0,4
1,1
2,25
60°
9
15
8,2
10,5
2,5
0,5
1,5
2,50
60°
9
15
8,7
11,2
3,5
0,6
2,0
3,00
60°
9
15
10,5
13,5
5,0
0,8
3,0
3,50
60°
9
14
12,5
15,2
6,0
1,0
3,9
Содержание 970930