Assembling
Dimensioning of oil pipes
One-line system:
The pump is designed to allow working with
two pipes. In order to obtain one pipe working
it is necessary to unscrew the return plug (2),
remove the by-pass screw (3) and then screw
again the plug (2).
It is sufficient to loosen the suction gauge con-
nection (5) and wait until oil flows out.
It is neccesary to install a filter on the fuel sup-
ply line.
Attention:
Do not start the burner before oil
flows out.
Max lenght of suction line
H
Dimensioning
8/10 mm
10/12 mm
0,5 m
10 m
20 m
1,0 m
20 m
40 m
1,5 m
40 m
80 m
2,0 m
60 m
100 m
1. Suction line
2. Return line
3. By-pass screw
4. Gauge connection
5. 2nd stage pressure adjuster
6. Suction gauge connection
7. 1st stage pressure adjuster
8. Pressure reducer piston
9. 2nd stage valve
10. 1st stage vaæve
11. Auxiliary pressure test point