Oilburner
Type Gulliver RG3D
GB
Max. oil cons.:
app. 17,8 l/h
Control box:
550 SMD
Type of oil:
Gas oil
Flue pipe dimens.:
Ømm
Installation data:
Installer:
Interruptions:
– PRESS THE BUTTON ON THE CON-
TROL BOX!
also check:
– that the room thermostat is adjusted hig-
her than the temperature in the room
– that the fuses are in good order
– that the safety thermostat have not been ac-
tivated
– that there is oil in the tank.
Please check before ignition:
– that the valves on the oil pipes are open
– that the flue system is clear
– that the access door and inspection eye
are tight
– that the thermostats are adjusted to the
right temperature.
Instruction
This instruction should be kept in the furnace room
The user is responsible for the burners working order and that the following points are observed.
Regulations:
The furnace room and the room containing the oil tank must bee clean and tidy at all times. Inflam-
mable materials, including selfigniting and explosive materials must not be stored in these rooms.
Maintenance:
The oil burner and air heater, should be inspected and adjusted once a year, to maintain good en-
vironmental and economical operation.
Because of wear and tear the following components shall always be replaced during af complete
overhaul:
– Oil nozzle
– O-ring for oil pump
– Filter for oil pump
If the installation is provided with a prefilter, the filter cartridge and the o-ring should also be repla-
ced.