P
AGE
18
05721-1098 <90-00050>
F
IG
. 10 - MAT S
WITCH
L
OCATIONS
INSTALLATION
S
TEP
7 - 46062 GPP S
ETTINGS
Master Port: RS-232, 1200 baud, TL1, TL1 mode by computer,
memory hold on power-up or reset, no parity
Data Port: DCPF, 1200 baud, no parity, 1 stop bit,
Printer Port: Printer syntax, 1200 baud, 1 stop bit, no parity
The GPP will require a download of the Operating software and
the Database for the GPP. See 46504 T/Shell editor practice for
instructions. Connect a computer that contains the T/Shell
editor to C2 of the 46090 in slot 2, shelf D, or to C2D of the D
shelf.
Refer to Fig. 11 for switch and strap locations. Set 46062 strap
settings per following table:
Shelf D
Slot 1
A11-46062-22 GPP SETTINGS AT SERVICE NODE
SWITCHES LISTED ARE IN THE ON (DOWN) POSITION
S1
all on
S2
all on
S3
1,2,3,4,5,6,7
Master Port jumpers = K3, CC2, DD1, L2, EE1, N1, M2
Data Port jumpers = C1, A1
GPP will be factory-set for RS-232 on all ports. Operating
software and database is required to operate GPP.
S101
S102
S103
S104
1
13
1
4
J5
J4
SUBASSEMBLY
MOUNTING
AREA
S5
S4
S3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
(-13 OPTION ONLY)
UP = OFF
DOWN = ON
1 2 3 4 5 6 7 8