5 SWIMMING POOL SYSTEMS

5.1  The Need for Low-Friction Piping and Filtration

CAUTION   A low-friction piping and filtration system is essential to satisfactory solar pump
performance.

  In a retrofit situation, be prepared to replace some components where appropriate. Plan

the pump installation with this in mind. You may need to leave space for a larger filter, larger pipe and/or
longer-radius (sweeping) pipe bends.

Conventional pool pump systems are often built with a relatively small filter and piping system. This
imposes substantial resistance to water flow. To compensate, a relatively large pump is installed – one
that has sufficient power to overcome the resistance. This reduces the INITIAL cost, but increases the
power requirement. With a solar pump, power is paid for up-front, so this is false economy. 

SunCentric P

is not sized to handle a high-resistance piping system (with back-pressure greater than 15 PSI).

SunCentric P

 swimming pool systems are sized for relatively efficient filters and piping, to minimize the

size and cost of the solar array. Before installing the pump, it is important to consider the efficiency of the
filter and piping, and to consider some simple methods to optimize its performance.

Reducing pipe friction and back-pressure    

Resistance (friction) in the filter and piping loop causes

back-pressure, which is indicated by a pressure gauge. It is desirable for the back-pressure to be low.
This causes the flow rate of the system to increase. Typical back pressure for a pool system is around 15
psi (1 bar). Consider these suggestions to reduce the back-pressure and increase the flow rate.

Efficient filtration

     Choose the filter carefully. A large filter will resist the flow less than a small one.

The filter maker's specifications will show the back-pressure vs. flow rate.

There are three common types of filters:

1. Cartridge 

filter

This is the best. It works well at low and variable flow rates, has low pressure-drop, and no need to
be backwashed.

2. Sand 

filter

This works well at low and variable flow rates, but check the specifications for pump requirements for
backwashing. The solar pump (by itself) may not produce sufficient backwash. If you have an AC
backup pump, this is not a problem.

3.  Diatomaceous earth (DE) filter

This has the highest pressure drop and does not work well below a specific pressure. It may not
function consistently with a solar pump.

Double filter to reduce pressure drop

   Two filters can be piped in parallel, to split the flow. This is the

equivalent of having one filter of twice the size. It will cut the resistance in half.

Efficient piping     

Large pipe will minimize friction. 2" pipe has much less resistance than 1.5" pipe.

Anything smaller is not acceptable. Avoid sharp 90° elbows where possible. Instead, use long-radius 90°
elbows, 45° elbows, or flexible pipe This is especially true if 1.5” pipe is used. Even if part of the system
uses 1.5” pipe, it will help to step up to 2” pipe in places, especially where there are elbows.

Solar heating

     Design a system for minimum friction, and calculate the pumping requirement carefully.

Installing a backup pump 

  See Section 4.9.

Содержание SunCentric P

Страница 1: ...Instruction Manual Solar Powered Centrifugal Pump for swimming pools agriculture more Dankoff Solar Products Inc Santa Fe NM USA 505 473 3800 888 396 6611 www dankoffsolar com C entric un S TM P 1 1...

Страница 2: ...ing and Grounding 16 4 9 Low Water Probe for Dry Run Protection 17 4 10 External ON OFF Switching 17 4 11 Automatic Control For Full Tank Shutoff 19 4 12 AC Backup 21 5 SWIMMING POOL SYSTEMS 22 5 1 Th...

Страница 3: ...r or the controller Install proper system grounding for safety and lightning protection See Section 4 2 Do not touch the controller input or pump wires together to test for a spark Do not run the pump...

Страница 4: ...lar exposure of the solar array is critical for the performance of a solar direct system Choose a location for the solar array that has unrestricted sun exposure through the day and through the year T...

Страница 5: ...he tracker pipe was extended to about 10 feet 3m by welding it to a larger pipe The array was assembled and wired on the ground then lifted and lowered onto the pole with the help of a backhoe and cha...

Страница 6: ...ow No magnetic compass needed Sun Compass Instructions 1 Draw an arrow from Month dot to intersection of your Standard Time and Latitude The gray line is an example August 2 PM at 40 N lat 2 Stand and...

Страница 7: ...oduction will be increased by about 8 in summer 5 in winter compared to option 1 There is less advantage in a cloudier climate If adjustment is difficult or is likely to be forgotten this is not a goo...

Страница 8: ...heating This may also allow easiest access without hitting your head on the lower south edge of the array Junction box A pre wired junction box is included with your system The junction box terminals...

Страница 9: ...on to confirm that it is secure PHOTO GALLERY Illustrated on the next pages is a 300 watt solar direct system with a pole mount The pump controller and the junction box are installed on the pole The a...

Страница 10: ...eliminates need for lugs slotted strut Unistrut or equivalent cut to the width of the box conduit clamp to fit slotted strut hose clamp Typical assembly of the controller and junction box on the sola...

Страница 11: ...etc 2 Install a copper plate or other specialized grounding devices designed for the purpose Some systems use salts to improve the conductivity of the surrounding soil 3 Install one or more copper pla...

Страница 12: ...system ungrounded This is called a floating system Explanation With a floating system and a good structural ground lightning induced surges tend to reach ground through the structure instead of the po...

Страница 13: ...ailures are caused by loose corroded or shorted connections PHOTOS show two types of PV module junction systems TOP Quick connect system using MC connectors BOTTOM Conventional junction box with condu...

Страница 14: ...r to the controller Voltage open circuit must not exceed 90V Even in cloudy weather the open circuit voltage will be near maximum WARNING Some thin film modules panels may produce excessive voltage es...

Страница 15: ...aximum RPM setting 1 Remove the bottom end of the EP 600A controller enclosure the end with the conduit openings 2 Locate the adjustment knob shown in the photo below circled 3 In most cases the knob...

Страница 16: ...akes 15 seconds to reach full speed If the direction is reversed STOP THE PUMP before it reaches full speed or the impeller may spin off and crash If the direction is reversed exchange ANY TWO of the...

Страница 17: ...probe wires to the low water probe terminals 1 and 2 Operation The probe senses electrical conductivity through the water between two electrodes If the water level drops below the probe continuity is...

Страница 18: ...N Other switches use normal to describe the position that makes a device turn OFF Switch contact ratings The remote switch circuit uses 12V at very low current measured in milliamps Contact ratings ar...

Страница 19: ...air shielded cable to reduce the chance of damage from lightning induced surge See Section 4 2 Grounding and Lightning Protection Float Switch Cable from Dankoff Solar Products Item 10326 meets these...

Страница 20: ...ing If you are not using a float switch terminals 4 and 5 must be connected Terminal 3 remains disconnected The product is pre wired this way at the factory Operation of the float switch system When t...

Страница 21: ...n parallel connect the pump intakes together using a Y or a sweeping T fitting Install a check valve at each pump s outlet to prevent one pump from bypassing the other Finally connect the check valve...

Страница 22: ...to increase Typical back pressure for a pool system is around 15 psi 1 bar Consider these suggestions to reduce the back pressure and increase the flow rate Efficient filtration Choose the filter care...

Страница 23: ...al AC pool pump parallel to the solar pump Turn it on when the cleaner is needed If the solar installation is a retrofit this can be the original filter pump See Section 4 9 AC Backup B Add an accesso...

Страница 24: ...unions To connect ABS pipe to the pump unions use cement that is approved for ABS pipe To connect PVC pipe to the pump unions use cement that is approved for connection of BOTH materials It is called...

Страница 25: ...from any local pump supplier To prevent air from being drawn into suction pipe due to a suction whirlpool the foot valve may need to be submerged as much as three feet 1 m below the low water level T...

Страница 26: ...lso be actuated by a manual switch timer thermostat etc Re label it if necessary BATTERY SYSTEMS ONLY BATTERY LOW tank light flashes Battery systems only battery voltage fell to 22V or 44V and has not...

Страница 27: ...g of the strainer basket Strainer basket To remove debris from the strainer basket unscrew the lock ring and the clear lid and lift out the basket Never operate the pump without the strainer basket If...

Страница 28: ...ies with the season Some people adjust the tilt twice per year Other people set it at a single setting as a permanent compromise Section 3 5 for details Solar Tracker If the system uses a solar tracke...

Страница 29: ...8 5 Exploded View of Pump...

Страница 30: ...2921141255 9 1 O RING DIFFUSER 98 x 5mm 2920117420 10 1 DIFFUSER 2921151105 10 1 1 ADAPTOR RING 2921123005 11 1 IMPELLER 12 2920143310 12 1 MECHANICAL SEAL 14mm 2921141220 13 1 O RING CASING 190 x 5 5...

Страница 31: ...d start if the supply voltage is greater than 22V 24V system or 44V 48V system 2 If the pump was recently connected or reconnected to the controller it may be running in reverse direction due to wirin...

Страница 32: ...y This is merely idle voltage It is high because no current is being drawn it sees no load 2 VOLTAGE UNDER LOAD with pump running This should be 60 73V with a 48V nominal array or 45 55V with 36V nomi...

Страница 33: ...00 MW that means 100 million or 100 megohms A lower reading indicates an insulation fault in a power wire to the pump 9 4 If The Pump Runs But Flow Is Less Than Normal 1 Is the solar array receiving s...

Страница 34: ...covered under warranty Product liability except where mandated by law is limited to repair or replacement at the discretion of the manufacturer Manufacturer is not responsible for incidental or conseq...

Отзывы: