72
www.Daniel.com
SERIES 1200 LIQUID TURBINE METER
Figure 9-32: Bearing assembly installation
3. Install the internal retaining ring holding the bearing assembly into the diffuser.
Figure 9-33: Internal retaining ring installation
4. Gently slide the rotor into the bearing shaft. There is an etched “U” on the upstream
side of the rotor.
Important
Handle the rotor with care. Improper handling of the rotor assembly may cause
distortion to the rotor blades, affecting meter performance.
Figure 9-34: Rotor installation
5. Install the retaining ring and support fins to the end of the bearing supporting the
rotor.
Planned maintenance
User manual
September 2020
P/N 3-9008-513