64
www.Daniel.com
SERIES 1200 LIQUID TURBINE METER
Figure 9-11: Internals removal
Stainless steel bearing internals disassembly
Procedure
1. Remove the support fins and the internals from the flow tube. Remove the retaining
ring from the end of the bearing which supports the rotor.
Figure 9-12: Retaining ring removal
2. Gently slide the rotor from the bearing shaft.
There is an etched “U” on the upstream side of the rotor.
Important
Handle the rotor with care. Improper handling of the rotor assembly may cause
distortion to the rotor blades thereby affecting meter performance.
Planned maintenance
User manual
September 2020
P/N 3-9008-513
74