54
www.Daniel.com
SERIES 1200 LIQUID TURBINE METER
8
Operation parameters
8.1
Operation overview
The Daniel Series 1200 LTM is a volumetric flow measuring and transmitting device that
produces an output signal proportional to the rate-of-flow of the liquid being measured.
The primary output is a single or dual high resolution signal that is amplified and shaped by
an integral preamplifier mounted within an explosion proof housing. This square wave
pulse can be fed directly to remote totalizer, digital readout devices or control
instrumentation.
WARNING
EXCEEDING PARAMETER HAZARD
Turbine meter parameters are set for safe equipment use. Do not exceed these
parameters.
Failure to comply may result in death, serious injury and/or damage to the equipment.
8.2
Turbine meter normal operation
After any reparation or installation of a new turbine meter, calibrate it to confirm the
meter factor or establish a new meter factor for the turbine meter as it is installed at the
site.
The customer has various options to calibrate their turbine meter. Either by their on site
stationary small volume bidirectional - unidirectional or master meter. This calibration
service is also available from Daniel.
During operation, the customer data center will download to the terminal automated
system (TAS) the orders to be schedule to the pipeline to various customers. TAS and
turbine meter electronic pre-set monitor, control and collect batch volumes on each order
and return all information as if it occurs to the TAS or invoncing.
8.3
Back pressure calculation for the LTM
Flow and pressure information is stamped on the nameplate located on the outside of the
meter.
•
Back pressure at the outlet of the turbine meter must be sufficient for accurate
operation.
•
Consider the following equation when determining back pressure for the turbine
meter.
P
b
≥ 2 △ p + 1.25p
e
P
b
Minimum back pressure, pounds per square inch gauge (psig)
Δp
Pressure drop through the meter at the maximum operating flow rate for the
liquid being measured, pounds per square inch (psi).
User manual
Operation parameters
P/N 3-9008-513
September 2020
User manual
63