background image

4. Click on Install.

5. Click on Finish.

The WS Wireless Configurator installation has installed successfully and will restart.

After the installation of the driver, start the PLUS+1

®

 Service Tool program. Select Communication >

Gateway > RP1210B: Danfoss (WS103RP1210) > WS103 Connection Manager.

User Manual

WS103 Remote Solution

PLUS+1

®

 Service Tool connected to a WS103

 

©

 Danfoss | July 2016

AN00000339en-US0101 | 49

Содержание WS103

Страница 1: ...User Manual Danfoss Telematics Solutions WS103 Remote Solution powersolutions danfoss com...

Страница 2: ...Revision history Table of revisions Date Changed Rev July 2016 First edition 0101 User Manual WS103 Remote Solution 2 Danfoss July 2016 AN00000339en US0101...

Страница 3: ...ned to the USB RS232 converter cable 17 Create new configuration 18 Device configuration 19 CAN Receive configuration 21 WLAN configuration 22 Bluetooth configuration 26 Pair the WS103 to laptop 27 Ex...

Страница 4: ...ol connected to a WS103 Install WS Wireless driver 48 WS103 Connection Manager 50 Add WLAN Infrastructure connection 51 If error is indicated 53 Add Bluetooth connection 54 If error is indicated 56 WS...

Страница 5: ...qualified technicians and electricians with advanced knowledge in electrical engineering and CAN Bus systems Their knowledge must be sufficient to estimate the risks and hazards of operating the devic...

Страница 6: ...ional data over long runs and moving joints The interface is suitable for use in mobile and stationary systems for industrial agricultural and forestry machinery The WS103 is an Easy to Install plasti...

Страница 7: ...sured failures or malfunctions of the device can lead to erroneous data transmission Never rely solely on wireless device for essential communications because data transmission at all times and under...

Страница 8: ...cur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged t...

Страница 9: ...103 Remote Solutions device elements 1 2 3 4 5 6 7 kwa1459357672625 1 Plastic housing 5 RS 232 connector configuration and FW update 2 Mounting holes 6 Front label 3 Name plate located on the side of...

Страница 10: ...ider is the type of cable to be used for connecting together each component of the system C Caution Using incompatible accessories may damage your equipment Incorrect selection or wiring of such cable...

Страница 11: ...Description 1 Ground Brown Power supply 2 White 3 BOOT DSR Blue Boot pin RS 232 Data Set Ready input 4 RXD RS 232h Black Receive input 5 TXD RS 232 Gray Green Transmit output PIN3 is used only to act...

Страница 12: ...system signal reflections at the end of a wire or cable can cause interference which is one reason for transmission errors To minimize these reflections a terminator is placed at each end of a transmi...

Страница 13: ...curity Just Works green flashing 200 ms on 1000 ms off Double flash Initializing status 200 ms on 200 ms off 200 ms on 200 ms off 1000 ms off Triple flash Reset status 200 ms on 200 ms off 200 ms on 2...

Страница 14: ...403x and WS503x WS FW programmer to be used with WS403x WS503x and WS103 WS wireless configurator to be used with WS103 The WS System Tools can be download directly from the Telematics section online...

Страница 15: ...Follow the instruction shown in the Configurator Setup Wizard 2 Select installation destination folder By default it is C Program Files x86 Danfoss WS Wireless Configurator 3 Optional Create start me...

Страница 16: ...top icon a Click Next 5 Click Install to continue with the installation 6 Select Launch WS Wireless Configurator a Click on Finish User Manual WS103 Remote Solution WS Wireless configurator 16 Danfoss...

Страница 17: ...version of the tool Set COM port assigned to the USB RS232 converter cable 1 In the WS Wireless Configurator main window either Select Options Connection settings Click on Serial located in the lower...

Страница 18: ...Manager Ports section the USB Serial Port properties Example of USB Serial Port properties Create new configuration To create a new configuration either Go to File New configuration Click on the New...

Страница 19: ...CAN Baud rate selection Feedback Mode The Feedback Mode enables the successfully transmitted CAN Messages to be sent back to the host in order of transmission The Feedback Mode by default is not check...

Страница 20: ...N Bus network Heartbeat time ms With node monitoring according to the heartbeat principle a node automatically transmits its communication state at regular intervals as evidence of its communication a...

Страница 21: ...onfiguration It is possible to define the CAN message received by WS103 Display Format The values of Mask and CAN Identifier can be shown in decimal or hexadecimal format By default it is set to hexad...

Страница 22: ...the DHCP mode is set to server WS103 will assign IP addresses to client devices based on the configured settings SSID Select your wireless network Service Set Identifier SSID In Infrastructure Operat...

Страница 23: ...Operating Mode the password is required to access to the wireless network In the MiniAP Operating Mode the password is needed to access the wireless network generated by WS103 Automatic WLAN Connectio...

Страница 24: ...cture If operating mode is MiniAP then DHCP mode can be either Disabled Server If DHCP mode is Server MiniAP only the static address information is used and WS103 constitutes a DHCP server This server...

Страница 25: ...etwork mask This is the static Network mask for determining the local subnet This setting is used if DHCP mode is disabled or DHCP is in server mode Gateway address The gateway address is necessary to...

Страница 26: ...inquiry scan PairableIf Pairable is checked it will be activated and the device can be paired with another Bluetooth device Security Settings Security mode Bluetooth 2 0 The security modes available...

Страница 27: ...uetooth Connection This functionality is used to establish automatically a Bluetooth connection with a client Bluetooth device such as another WS103 to establish a Bluetooth CAN bridging functionality...

Страница 28: ...t 3 Go to Devices and Printers on the laptop click on Show Bluetooth Devices 4 Select the WS103 and right click on Properties then click on Services tab to see the COM port assigned with the service C...

Страница 29: ...t to all CAN bus nodes CAN open when WS103 enters into Operational mode automatically at Start up By default Enter operational mode automatically is selected The device is set to go automatically in o...

Страница 30: ...into sleep mode after clamp 15 pin 3 in the main connector goes to 0 By default Disabled is selected SDO Server Settings Do not change the parameter values in the SDO Server Settings Contact DTS suppo...

Страница 31: ...global safety mechanism CAN identifier can be 11 bit or 29 bit The type codes are Bit 29 0 11 bit type Bit 29 1 29 bit type Bits 0 to 28 CAN identifier Timeout ms The global safety mechanism Timeout...

Страница 32: ...s are possible Equal is selected by default Comparison value The value is compared with the global safety mechanism state read on CAN Bus network using the condition selected If the condition is true...

Страница 33: ...ils The configuration file has the extension clk When a configuration is saved the path with the name of the configuration shows on the lower part of the WLAN Configurator user interface When a saved...

Страница 34: ...ess Configurator close the user interface by selecting File Exit Warning message when an opened configuration is not saved Connect Disconnect Read and Write data to WS103 1 Establish a connection betw...

Страница 35: ...ol available on DTS website telematics section If the USB RS232 COM port is not configured correctly or in case of communication problems the following animated icon appears rotating in the middle of...

Страница 36: ...laptop memory by pressing the related Copy push button After the configuration of WS103 disconnect the USB RS232 converter cable from the connector J 2 When the device is installed on a machine put th...

Страница 37: ...ings A connection settings window appears 3 Select the COM port assigned to the USB RS232 converter cable and close the window Locate assigned COM port Locate the correct port assigned to the USB RS23...

Страница 38: ...lt it is recommended to increase this value for example increase to 16 msec in case of problem during the upgrade of the WS103 Firmware Connection Connect icon Device data and Connected to device is s...

Страница 39: ...device icon 5 Select the node ID set to 33 by default 6 Select the CAN bus baud rate set to 250 kb s by default CAN receive All CAN Messages with ID Length 11 bit or 29 bit are received by WS103 objec...

Страница 40: ...default settings Safety The safety mechanism is not configured by default If the plan is to establish a wireless connection to a machine that is not in direct visibility to the operator for example WL...

Страница 41: ...n the right 1 Select Infrastructure for the Operating mode 2 Type in the SSID of the WLAN network 3 Select the Authentication type typically WPAWPA2 Mixed 4 Type in the Authentication key 5 Select Dis...

Страница 42: ...umber 30000 by default 12 Select TCP as a Protocol TCP by default 13 Select Write data to the device Disconnect WS from the WS Wireless Configurator and immediately the device will re start and try to...

Страница 43: ...by default 2 Type in the Device name WS103_SN by default 3 Check Discoverable checked by default 4 Check Pairable checked by default 5 Select Disabled on Security mode Bluetooth 2 1 checked by default...

Страница 44: ...vice will be installed and a specific COM port will be assigned to it To see the COM port assigned with the service open Devices and Printers to see Bluetooth devices On the laptop you can click to Sh...

Страница 45: ...elect Properties then select Services tab to see the COM port assigned with the service Example of device paired with the laptop to the assigned port COM17 User Manual WS103 Remote Solution WS103 conn...

Страница 46: ...device available for the CAN bridge connection 7 Choose the Remote port 8 Write the data to the device Disconnect WS from the WS Wireless Configurator and immediately the device will re start and try...

Страница 47: ...Disconnect WS from the WS Wireless Configurator and immediately the device will restart and try to establish a Bluetooth connection with the configured WS103 Every power on with the Automatic Bluetoo...

Страница 48: ...nfoss PLUS 1 drivers or restart the PLUS 1 Service Tool after the installation 1 Click on Next in the Setup Wizard to begin installation of drivers 2 Click Next 3 Read carefully the Software License a...

Страница 49: ...ssfully and will restart After the installation of the driver start the PLUS 1 Service Tool program Select Communication Gateway RP1210B Danfoss WS103RP1210 WS103 Connection Manager User Manual WS103...

Страница 50: ...y the user The next execution of the PLUS 1 Service Tool shows the list of available created wireless connections WS103 Connection Manager push buttons Push button Description Add new connection Delet...

Страница 51: ...connection Open PLUS 1 Service Tool and start the WS103 Connection manager 1 Click on Add Connection a Write name of connection b Select the WLAN type of connection c Select the IP address assigned t...

Страница 52: ...the scan of the system the ECU PLUS 1 compliance will be available on ST ECU list and the symbol connected will be green A status dialog will open User Manual WS103 Remote Solution PLUS 1 Service Tool...

Страница 53: ...reated on the Connection Manager IP Address The IP Address Port used by WS103 Connection Time Current connection time If error is indicated Scan of multiple ECU available on the network indicate error...

Страница 54: ...ned to a SPP_WS103 d Click Apply 2 Click on Connect A pop up window will show the connection process in progress When ST is connected the scan of the CAN bus will start After the scan of the system th...

Страница 55: ...echanism could be Write or Read Only access CAN Bus Status The current state of the CAN Bus Connection The connection name created on the Connection Manager COM Port The COM port used for SPP service...

Страница 56: ...2 Set the parameter KW2000_STmin to 1 in the Edit field a Click OK WS Wireless Driver version Identify the version of the WS Wireless Drivers by going to the Connection Manager and clicking About In t...

Страница 57: ...4 3 4 3 WS103 connectors and indicator element WS103 is equipped with the following connectors and indicator element 1 2 3 kwa1459393937324 1 CAN Power connector 2 RS232 connector 3 Power CAN Status L...

Страница 58: ...7 The module can be mounted in any position in the case of outdoor installation place it in a way that does not allow water or liquid on to the connectors see Ingress protection rating on page 58 Ingr...

Страница 59: ...User Manual WS103 Remote Solution Danfoss July 2016 AN00000339en US0101 59...

Страница 60: ...81 DK 6430 Nordborg Denmark Phone 45 7488 2222 Danfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building...

Отзывы: