Montage- und Betriebsanleitung / User manual
VXe SLS
© Danfoss | Produced by Danfoss Redan A/S | 2022.03 | 27
AQ40514397064001-000101
145X2068
Balancing valve TacoSetter
The TacoSetter balancing valve can be connected directly to the
suction port of a pump. With the Taco Setter balancing valve the
flow can easily be adjusted, displayed and shut off.
The flow rate is regulated using a screwdriver at the adjusting screw
(with water in the system). Direct reading of the set volume flow
in l/min with glycol scale (sight glass). The reading position is the
bottom line of the baffle float, - as indicated in photo (A) (red arrow)
.
The flow limiter is factory set to the maximum water flow / fully
open. The position of the notch in the adjusting screw is in the lon-
gitudinal direction of the valve, - as indicated in photo (B).
Note: The system medium must be allowed to flow through the
measuring body for at least 2 hours prior to reading the flow rate
when performing the initial start-up or refilling the system.
Pump, DHW Storage Circuit
The VXe SLS with a storage charging system integrated on the prima-
ry side is factory-fitted with the Grundfos UPM3 circulation pump.
The storage tank is loaded via the factory-installed pump.
The pump is controlled by the cylinder sensor and ECL controller in
combination.
For more information, see Grundfos pump instructions and Danfoss
ECL application key instructions.
13. DOMESTIC HOT WATER
Adjusting screw
Reading the
flow rate
A
B