32 DKDHR
VI.GP.P2.02
Danfoss District Energy
Instructions for installation and use
VX Solo II substations
Ac valve, unit with electronic control of the heating and
DHW cylinder circuits
For controlling the domestic hot water circuit the VX Solo II HWP
(ELC 210/A247) and the VX Solo II H2WP (ECL 310/A377) are sup-
plied with electrical actuator type Danfoss AMV 150 with Danfoss
valve housing type AHQM placed on the primary return flow pipe.
The AMV actuator is electrically wired to the controller from the
plant.
The electrical actuator has undergone a functional test and is preset
from factory.
In the event of operating disturbances the actuator can be shut off
manually in accordance with enclosed instructions, by turning the
manual override knob on top of the actuator clockwise.
Please see enclosed instructions,
Electrical actuator AMV 13
Flow-controller with integrated control valve AHQM
14.0 Pump, DHW Cylinder circuit
Domestic hot water circulation pump
VX Solo II with connection pipes for domestic hot water cylinder on
the secondary side (types HWS and H2WS) are fitted with a circula-
tion pump from factory.
It is recommended to set the pump at highest speed of rotation (set-
ting 3) before start-up. Then set the pump at lowest possible speed
of rotation (setting 1), in due consideration of the electricity con-
sumption and the heating comfort. Factory setting of the selector
switch is centre position (default). Select setting 2 and 3 only if the
pump setting does not meet actual system requirements.
Please see enclosed instructions,
GRUNDFOS UPS
Press and hold the button (on
the bottom side of the actuator)
during manual override.
Manual override (AMV 150)
Instructions
AMV 150
73691180 DH-SMT/SI
VI.KU.N2.1J © Danfoss 01/2008
1
ENglIsh
Actuators for three point control AMV 150
www.danfoss.com
Page 2
DANsK
Motorer til 3-punkts styring AMV 150
www.danfoss.dk
Side 3
DEUTsCh
Stellantriebe für 3-Pkt.- Eingangssignal AMV 150
www.danfoss.de
Seite 3
sVENsKA
Motor för 3-punktsreglering AMV 150
varme.danfoss.se
Sida 4
NEDERlANDs
Servomotor met 3-puntssturing AMV 150
www.danfoss.nl
Pagina 4
lIETUVIŲ K.
Pavaros trijų padėčių valdymui AMV 150
www.danfoss.lt
5 puslapis
lATVIsKI
Motori trīs punktu kontrolei AMV 150
www.danfoss.com
Lpp. 5
MAgYAR
Szelepmozgatók hárompontos szabályozáshoz AMV 150
www.danfoss.com
6. oldal
ČEsKY
Servopohony s tříbodovým regulačním signálem AMV 150
www.danfoss.cz
Strana 6
POlsKI
Siłowniki sterowane sygnałem 3-punktowym AMV 150
www.danfoss.pl
Strona 7
РУССКИЙ
Электроприводы для трехпозиционного регулирования AMV 150
www.danfoss.ru
Страница 7
AMV 150 +
AMV 150 +
AMV 150 +
VS2 (DN 15)
VMV
AVQM (DN 15)
AHQM
1
Installation Guide
AHQM, DN 40-100
Danfoss Heating
VI.LR.K1.00
DH-SMT/SI
Δp
v
+
–
Q
max
Δp
v
≥ 0.5 bar
P
test
= 1.5 × PN
Δp
v
: 0.5-4.0 bar
DN 40, 50
DN 50-100
AMV(E) 435 +
AHQM DN 40, 50
AMV(E) 435 +
AHQM DN 50-100
AMV(E) 438 SD +
AHQM DN 40, 50
AMV(E) 438 SD +
AHQM DN 50-100
Grundfos UP UPS
UPD, UPSD
UP, UPS, UPD, UPSD
GRUNDFOS
INSTRUCTIONS
Selector switch
Содержание VX Solo II Series
Страница 40: ...40 DKDHR VI GP P2 02 Danfoss District Energy Instructions for installation and use VX Solo II substations ...
Страница 42: ...42 DKDHR VI GP P2 02 Danfoss District Energy Instructions for installation and use VX Solo II substations ...
Страница 43: ...43 43 Danfoss District Energy VI GP P2 02 DKDHR Instructions for installation and use VX Solo II substations ...