Preparing the heat pump
9.3
1
2
3
4
6
5
Removing the heat pump
Figure 6.
Image description
Front panel
1
Knockout
2
Top panel
3
T-connector
4
Water pipe with insulation
5
Side panel
6
Remove parts of the heat pump as follows:
Detach and lift off the front panel�
1�
Tap out the knock out in the top panel�
2�
Slacken off the screws holding the top panel� Lift the panel off
3�
carefully�
If the heat pump is already installed, raise the top panel as far as
possible and secure it in the raised position�
Remove the right-hand side plate�
4�
Detach the water pipe at the T-connector�
5�
Remove about 200 mm of the insulation on the water pipe�
6�
Cut the pipe 170 mm from the end�
7�
Remove the existing T-connector with its pipe piece�
8�
Installing replacement pipes
9.4
1
2
3
Installing replacement pipes
Figure 7.
Image description
Replacement pipe
1
Copper pipe
2
Straight clamp ring connector
3
Install replacement pipes as follows:
Install a straight clamp ring connector (086U2371) on the end of
1�
the water pipe�
Install the replacement pipe (086U6886) on the straight clamp ring
2�
connector�
Install new insulation on the replacement pipe�
3�
Install a straight clamp ring connector (086U2371) with a copper
4�
pipe (086U3600) on the connection for MBH/DWH�