18
Heat pump with water heater and HGW
technology
Description
6.
Connector is an accessory/system solution for customers with large
hot water requirements�
Connector makes it easy to connect a heat pump, with HGW technol-
ogy, with a separate MBH/DWH water heater to maintain a large hot
water volume�
Both hot water heaters in the heat pump and MBH/DWH are connect-
ed in series so that the MBH/DWH water heater is the primary heater
and the built-in heater in the heat pump acts as a secondary heater�
Most of the important hoses, pipes and connectors are included in
Connector installation kit� Some pipes must, however, must be fabri-
cated at the installation site by the installer�
Installation description
7.
The heat pump and MBH/DWH are connected in series by cutting the
water flow
s
from the HGW shunt
e
and allowing it to flow to MBH/
DWH’s connection for hot water charging
i
� The return from the coil
in MBH/DWH is connected to the heat pump’s heater connection, the
inlet to the heating coil
y
�
10
1
2
3
5
6
7
11
8
9
4
Connection for hot water production
Figure 1.
Image description
Heat pump
1
Secondary hot water heater
2
HGW shunt
3
From heating system
4
To heating system
5
Heater connection
6
Flexible hose
7
Charging MBH/DWH
8
Primary water heater
9
MBH/DWH
10
Cut and remove the existing pipe
11
The connections for cold water and domestic hot water are connected
as follows:
Incoming cold water
•
e
connects to heat pump�
Connection for domestic hot water
•
w
on the heat pump is con-
nected to the cold water connection
y
on MBH/DWH�
Domestic hot water is taken from MBH/DWH
•
t
�
1
2
3
4
5
6
7
Connection for domestic hot water
Figure 2.
Image description
Heat pump
1
Domestic hot water (HW) is connected to MBH/DWH
2
Cold water
3
Copper pipe connection
4
Tap hot water
5
Cold water (CW), is connected to the heat pump
6
MBH/DWH
7
In order for the heat pump’s regulation to control the temperature in
MBH/DWH, the heat pump’s peak sensor must be disconnected and
MBH/DWH’s peak sensor connected�
Содержание VMBQO23H