22
Install connectors on heat pump
9.5
1
2
3
4
Installing connections
Figure 8.
Image description
Seal washer
1
3-way clamp ring connector with bleed screw
2
Top panel
3
Side panel
4
Install connectors as follows:
Reinstall the side panel and the top panel� Do not install the front
1�
panel yet�
Install seal washer (086U3160) in the top panel for the replace-
2�
ment pipe�
Install a 3-way clamp ring connector (086U2458) with bleed screw
3�
(086U2459) on the replacement pipe�
Install a 3-way clamp ring connector (086U2458) with bleed screw
4�
(086U2459) on the copper pipe for MBH/DWH�
Connect MBH/DWH to the heat
9.6
pump
C
B
KV
VV
A
D
2
5
3
1
4
Connecting MBH/DWH
Figure 9.
Image description
Heat pump
1
Copper pipe
2
Flexible hose
3
MBH/DWH
4
Flexible hose
5
Connect hoses and pipes between MBH/DWH and the heat pump as
follows:
Set up MBH/DWH next to the heat pump�
1�
Install the flexible hose (086U6887) from the 3-way clamp ring
2�
connector with bleed screw on the heat pump (A) to the 3-way
clamp ring connector with bleed screw on the inlet on MBH/DWH
(B)�
Install the flexible hose (086U6887) from the 3-way clamp ring
3�
connector with bleed screw on MBH/DWH (C) to the 3-way clamp
ring connector with bleed screw (D) on the heat pump�
Install a copper pipe between the HW (hot water) connection on
4�
the heat pump to the CW (cold water) connection on MBH/DWH�
Содержание VMBQO23H
Страница 72: ...Thermia 086U7367 Rev 3 Danfoss VMBQO23H ...