
Normal
ove
rl
o
ad
110
%
for
1
min
u
te
Fre
que
ncy c
onve
rter
Typi
cal Sh
aft
Outp
ut
[kW] at 400V
P1
10
11
0
P1
32
132
P160 160
P200 200
P250 25
0
31
5
P400 400
P450 45
0
P5
00
500
P5
60
560
P6
30
630
P710 710
P8
00
80
0
P1
M0
1000
Typi
cal Sh
aft
Outp
ut
[H
P]
at 460
V
150
200
250
300
35
0
45
0
550
60
0
650
750
900
1000
120
0
1350
IP
00
D3
D3
D4
D4
D4
E2
E2
E2
F1/
F3
F1/
F3
F1/
F3
F1/
F3
F2
/F4
F2/
F4
IP 21 / Nema
1
D
1
D
1
D2
D2
D2
E1
E1
E1
F1/
F3
F1/
F3
F1/
F3
F1/
F3
F2
/F4
F2/
F4
IP
54 / Ne
ma 12
D1
D1
D2
D2
D2
E1
E1
E1
F1/
F3
F1/
F3
F1/
F3
F1/
F3
F2
/F4
F2/
F4
Out
p
u
t c
u
rr
en
t
Co
nt
in
uo
us (
3 x
3
80-
440
V)
[A]
21
2
260
315
395
48
0
60
0
745
80
0
880
990
11
20
1260
146
0
1720
Interm
ittent (3 x 380
-44
0 V)
[A]
233
286
347
435
52
8
66
0
820
88
0
968
1089
12
32
1386
160
6
1892
Co
nt
in
uo
us
(3
x 4
41-4
80V
) [A]
19
0
240
302
361
44
3
54
0
678
73
0
780
890
10
50
1160
138
0
1530
Interm
ittent (3 x 4
41-
480V
) [A]
209
264
332
397
48
7
59
4
746
80
3
858
979
11
55
1276
151
8
1683
Co
nt
in
uo
us
kV
A (400 V
AC) [kVA
]
14
7
180
218
274
33
3
41
6
516
55
4
610
686
776
873
101
2
1192
Co
nt
in
uo
us
kV
A (460 V
AC) [kVA
]
151
191
241
288
35
3
43
0
540
58
2
621
709
837
924
110
0
1219
Max. cab
le siz
e:
( moto
r,)
[mm
2
/ AW
G
2)
]
2x
70
2x
2/
0
2x
185
2x
300
mc
m
4x24
0
4x5
00 mcm
8x
150
8x
30
0 m
cm
12x
150
12x
300 mcm
(mains,
)
[mm
2
/ A
W
G
2)
]
2x
70
2x
2/
0
2x
185
2x
300
mcm
4x
240
4x
500
mcm
8x24
0
8x5
00 mcm
(lo
ads
ha
ring
) [m
m
2
/ AW
G
2)
]
2x
70
2x
2/
0
2x
185
2x
300
mcm
4x
240
4x
500
mcm
4x12
0
4x2
50 mcm
( brake) [mm
2
/ A
W
G
2)
]
2x
70
2x
2/
0
2x
185
2x
300
mcm
2x
185
2x
350
mcm
4x1
85
4x3
50 mcm
6x
185
6x
350
mc
m
Ma
x.
in
pu
t c
u
rr
en
t
Co
nt
in
uo
us (
3 x
3
80-
440
V)
[A]
20
4
251
304
381
46
3
59
0
733
78
7
857
964
10
90
1227
142
2
1675
Co
nt
in
uo
us
(3
x 4
41-4
80V
) [A]
183
231
291
348
42
7
53
1
667
71
8
759
867
10
22
1129
134
4
1490
Max. p
re-fu
ses
1)
[A
]
30
0
350
400
500
63
0
70
0
900
90
0
1600
1600
20
00
2000
250
0
2500
En
vi
ro
nm
en
t:
Estim
ate
d p
ow
er
lo
ss at
400
VA
C
at
r
at
ed m
ax.
lo
ad
[W]
4)
3234
37
82
4213
5119
58
93
679
0
8879
967
0
10647
12
338
13201
15436
18084
20358
Estim
ate
d p
ow
er
lo
ss at
460
VA
C
at
r
at
ed m
ax.
lo
ad
[W]
4)
2947
36
65
406
3
4652
5634
60
82
8089
880
3
9414
11
006
12353
14041
17137
17752
W
ei
ght e
ncl
os
ure
IP00 [kg]
82
91
112
123
13
8
22
1
236
27
7
-
-
-
-
-
-
We
ig
ht
encl
osure
I
P 21
[kg
]
96
104
125
136
15
1
26
3
272
31
3
1004
1004
1004
1004
124
6
1246
W
ei
ght
en
cl
os
ure IP 54
[kg]
96
104
125
136
15
1
26
3
272
31
3
1299
1299
12
99
1299
154
1
1541
Eff
ici
ency
3)
0.
98
0.
98
0.
98
0.
98
0.
98
0.9
8
0.
98
0.9
8
0.9
8
0.
98
0.
98
0.9
8
0.
98
0.9
8
1)
For
ty
pe of fuse
see
se
ct
ion
Fuses
2)
Am
eri
ca
n
W
ire Gauge
3)
M
easur
ed
usi
ng 5 m scre
ene
d mot
or ca
bl
es
a
t ra
ted
lo
ad
an
d
rat
ed
fre
que
ncy
4)
T
he
ty
pi
ca
l p
owe
r l
os
s i
s a
t n
orma
l lo
ad
co
nd
itio
ns
a
nd
ex
pe
ct
ed
to
b
e w
ith
in
+/
-
15%
(tol
er
an
ce
re
la
tes
to
v
ari
et
y i
n v
oltag
e a
nd c
abl
e c
ond
iti
ons)
.
Va
lu
es
are
base
d
on a
ty
pic
al mot
or e
ffi
ci
en
cy
(
ef
f2
/e
ff3
borde
r l
ine
).
L
owe
r e
ffi
ci
en
cy
moto
rs wi
ll a
lso
add
to
the
po
we
r lo
ss
in
th
e fre
quen
cy
co
nvert
er an
d vice ve
rsa.
If t
he
switchi
ng fre
que
ncy is ra
is
ed fro
m
no
minal
th
e power losses ma
y rise signif
ican
tly.
LCP
and typical
c
ontro
l card power co
nsumptions a
re incl
uded.
Furt
he
r opti
on
s an
d custome
r l
oad ma
y add up
to 30 Wa
tts to
t
he l
osses. (Thou
gh typical
ly only
4 Wa
tts extra fo
r
a
fu
lly l
oa
de
d
co
ntrol
ca
rd or options
fo
r sl
ot
A or
slot
B
, e
ach)
.
Al
thou
gh me
asure
m
en
ts
are
made
w
ith
stat
e o
f t
he
art
equ
ipme
nt, some m
easurement
in
accuracy
mu
st be
a
llo
we
d f
or (
+
/-
5
%
).
3 VLT Automation VT Drive Selection
Automation VT Drive FC322 Design Guide
56
MG.20.X1.22 - VLT
®
is a registered Danfoss trademark
3
Remote Site Products - 1-888-532-2706 - www.remotesiteproducts.com
http://www.remotesiteproducts.com/p-20783-Danfoss-131X8145-VLT-Automation-VT-Drive-VFD-FC322-460V-.5-HP.aspx