Type Designation
P15K
P18K
P22K
P30K
P37K
P45K
P55K
P75K
P90K
Typical Shaft Output [kW]
15
18.5
22
30
37
45
55
75
90
IP20/Chassis
B3
B3
B4
B4
B4
C3
C3
C4
C4
IP21/Type 1
B1
B1
B2
B2
B2
C1
C1
C2
C2
IP55/Type 12
B1
B1
B2
B2
B2
C1
C1
C2
C2
IP66/NEMA 4X
B1
B1
B2
B2
B2
C1
C1
C2
C2
Output current
Continuous (3 x 525–550 V) [A]
23
28
36
43
54
65
87
105
137
Intermittent (3 x 525–550 V) [A]
25
31
40
47
59
72
96
116
151
Continuous (3x525–600 V) [A]
22
27
34
41
52
62
83
100
131
Intermittent (3x525–600 V) [A]
24
30
37
45
57
68
91
110
144
Continuous kVA (525 V AC) [kVA]
21.9
26.7
34.3
41
51.4
61.9
82.9
100
130.5
Continuous kVA (575 V AC) [kVA]
21.9
26.9
33.9
40.8
51.8
61.7
82.7
99.6
130.5
Max. input current
Continuous (3x525–600 V) [A]
20.9
25.4
32.7
39
49
59
78.9
95.3
124.3
Intermittent (3x525–600 V) [A]
23
28
36
43
54
65
87
105
137
Max. pre-fuses
1)
[A]
40
50
60
80
100
150
160
225
250
Additional specifications
Estimated power loss at rated
max. load [W]
4)
285
329
460
560
740
860
890
1020
1130
Max. cable size (line power,
motor, brake) [mm
2
]/(AWG)
2)
-
[35]/(2)
[50]/(1)
[95
5)
]/(3/0)
Efficiency
3)
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
Table 8.8 Line power supply 3x525–600 V AC - Normal overload 110% for 1 minute, P15K-P90K
8.1.6 Line Power Supply 3 x 525–690 V AC
Type Designation
P1K1
P1K5
P2K2
P3K0
P4K0
P5K5
P7K5
Typical Shaft output (kW)
1.1
1.5
2.2
3.0
4.0
5.5
7.5
IP20/ Chassis
A3
A3
A3
A3
A3
A3
A3
Output current
Continuous (3 x 525–550 V) [A]
2.1
2.7
3.9
4.9
6.1
9.0
11.0
Intermittent (3 x 525–550 V) [A]
3.4
4.3
6.2
7.8
9.8
14.4
17.6
Continuous (3x551–690 V) [A]
1.6
2.2
3.2
4.5
5.5
7.5
10.0
Intermittent (3x551–690 V) [A]
2.6
3.5
5.1
7.2
8.8
12.0
16.0
Continuous KVA 525 V AC
1.9
2.5
3.5
4.5
5.5
8.2
10.0
Continuous KVA 690 V AC
1.9
2.6
3.8
5.4
6.6
9.0
12.0
Max. input current
Continuous (3 x 525–550 V) [A]
1.9
2.4
3.5
4.4
5.5
8.1
9.9
Intermittent (3 x 525–550 V) [A]
3.0
3.9
5.6
7.0
8.8
12.9
15.8
Continuous (3x551–690 V) [A]
1.4
2.0
2.9
4.0
4.9
6.7
9.0
Intermittent (3x551–690 V) [A]
2.3
3.2
4.6
6.5
7.9
10.8
14.4
Additional specifications
Max. cable cross-section
5)
for line power, motor, brake
and load sharing [mm
2
] ([AWG])
4, 4, 4 (12, 12, 12) (min. 0.2 (24)
Max. cable cross-section
5)
for disconnect
[mm
2
] ([AWG])
6, 4, 4 (10, 12, 12)
Estimated power loss at rated max. load (W)
4)
44
60
88
120
160
220
300
Efficiency
3)
0.96
0.96
0.96
0.96
0.96
0.96
0.96
Table 8.9 A3 Enclosure, Line Power Supply 3x525–690 V AC IP20/Protected Chassis, P1K1-P7K5
Specifications
VLT
®
AQUA Drive FC 202
58
Danfoss A/S © 10/2014 All rights reserved.
MG20MA22
8
8
Содержание VLT AQUA Drive FC 202
Страница 2: ......
Страница 5: ...Index 83 Contents Instruction Manual MG20MA22 Danfoss A S 10 2014 All rights reserved...