1.4 Ordering Information
1.4.1 Filter Configurator
Use the ordering number system to design an active filter according to the application requirements. For the
VLT
®
Active
Filter AAF 006 Series
, it is possible to order standard filters and filters with integral options by sending a type code string
describing the product to the local Danfoss sales office. For example: AAF006A190T4E21HXXGCXXXSXXXXAXBXCFXXXDX
This section describes each character in the type code. In the example, a standard 190 A active filter in an enclosure with
IP21 protection rating is selected for a 380–480 V net. The internet-based configurator configures the right filter for the right
application and generates a type code string. The configurator automatically generates an 8-digit sales number to be
delivered to the local sales office. It is also possible to establish a project list with several products and send it to a Danfoss
sales representative. The configurator can be found at
www.danfoss.com/BusinessAreas/DrivesSolutions/
.
1.4.2 Ordering Form Type Code
130BB504.10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
A F
A
x
0 0
A
T
4
E
H
x
G C
x
x
x
x
x
x
x
B x
C x
x
x
x
x
D
A
S
Illustration 1.4 Type Code Example
Possible choice
Product groups
1-3
AAF
Series
4-6
006
Current rating
7-10
A190: 190 A
A250: 250 A
A310: 310 A
A400: 400 A
Phases
11
T: 3 Phases
Mains Voltage
12
4: 380–480 V AC
Enclosure
13-15
E21: IP21/Nema Type1
E54: IP54/Nema Type 12
E2M: IP21/Nema Type 1 with
mains shield
E5M: IP54/Nema Type 12 with
mains shield
RFI filter
16-17
HX: No RFI filter
H4: RFI filter, Class A1 (optional)
Display (LCP)
19
G: Graphical Local Control Panel
(LCP)
Coating PCB
20
C: Coated PCB
Mains option
21
X: No mains option
3: Mains disconnect and fuse
7: Fuse
Adaptation A
22
Reserved
Adaptation B
23
Reserved
Software release 24-27
Reserved
Software
language
28
Reserved
A options
29-30
AX: No A option
B options
31-32
BX: No B option
C-option configu-
ration
33-37
CFxxx: CO-option occupied with
active filter control card
D options
38-39
DO: 24 V back-up
DX: No options
Table 1.1 Type Code Definitions
176F3535
Backwall cooling kit for D14 (IP54)
176F3537
Backwall cooling kit for E1 (IP54)
Table 1.2 Optional Kits
Introduction
Operating Instructions
6
Danfoss A/S © 09/2014 All rights reserved.
MG90V302
1
1
Содержание VLT AAF006
Страница 2: ...MAKING MODERN LIVING POSSIBLE Operating Instructions VLT Active Filter AAF006 www danfoss com drives...
Страница 3: ......
Страница 91: ...W Wire access 11 Index Operating Instructions 88 Danfoss A S 09 2014 All rights reserved MG90V302...
Страница 92: ...Index Operating Instructions MG90V302 Danfoss A S 09 2014 All rights reserved 89...