Procedure
1. Strip the motor cable, the mains cable, and the brake resistor cable. See
.
2. Cut the grommets open to move the cables through them. Use the grommets delivered in the accessories bag.
•
Do not cut the grommet openings wider than what is necessary for the used cables.
•
If the grommets fold in when putting the cable, pull the cable back to make the grommets straight.
e
3
0
b
g
0
8
6
.1
0
3. To achieve EMC class C1 and C2, use EMC cable gland as an alternative to the grommet.
10 m
m
1
2
3
4
e3
0b
h8
37
.1
0
4. Put the cables – the mains cable, the motor cable, and the optional brake cable – in the openings of the cable entry plate. Use the
cable entry plate delivered in the accessories bag.
Electrical Installation
Operating Guide | VACON® NXS/NXP Air-cooled
AQ275638903263en-000301 / DPD00910
68 | Danfoss A/S © 2020.02