Table 28: Dimensions of the Mounting Holes in mm (inch) for VACON
®
NXS/NXP AC Drive, FR9
Drive type
E1Ø, grommet inside diameter
(1)
E1Ø, gland
plate hole
E2Ø, grom‐
met inside
diameter
(1)
E2Ø,
gland
plate
hole
E2Ø, grom‐
met inside
diameter
(1)
E3Ø,
gland
plate
hole
•
0261 2–
0300 2
•
0261 5–
0300 5
•
0125 6–
0208 6
•
IP21: 4 x GD48, 48 (1.89)
•
IP54:
-
2 x GD48, 48 (1.89)
-
2 x MC07115 , 56 (2.20)
4 x 59
(4 x 2.32)
25
(0.98)
25
(0.98)
60
(2.36)
75
(2.95)
1
Same as maximum cable thickness. NOTE! Cable clamps have 40 mm internal diameter. The clamps are used for 360 degree grounding of the shield. Exposing the cable shield
decreases outer diameter of the cable so the recommended 3x185+95 mm
2
MCCMK motor cables fit in the clamp.
12.2.3 Flange mounting
12.2.3.1 Dimensions for Flange Mounting, FR4–FR6
W2
H
1
H
2
W1
D
1
D
2
H4
H5
Ø
H3
W1
IP21
IP54
e
3
0
b
g
0
0
3
.1
0
Illustration 69: Dimensions of the VACON
®
NXS/NXP AC Drive with Flange, FR4–FR6
Specifications
Operating Guide | VACON® NXS/NXP Air-cooled
AQ275638903263en-000301 / DPD00910| 161