User Guide
MES 1003 WMS
Doc no. 100837-MAN – Rev. E1 – Rev. date 2022-10
© Danfoss IXA A/S | Page 7
1.6.
First Time Setup
The WMS is initially configured with date and time at the time of its production, however during shipping the clock may
have drifted. To ensure correct operation and logging, the time must be set before it is taken into use. The WMS will
continuously broadcast an alarm until the time is adjusted.
When the WMS is powered on for the first time, it will automatically enter the time setup menu on the local control panel
from where the time can be set immediately. For manual setup of the time see 2.2.2 -
2.
User Interfaces
2.1.
Local Control Panel
The contrast level of the display can be altered by pressing and holding the Status button, and at the same time pressing
the up and down buttons.
The backlight of the display can be turned off/on by pressing and holding the Status button and at the same time
pressing the Back button.
2.1.1.
LCP Layout
The LCP is divided into 4 functional groups (A-D), see Illustration 3: LCP Layout
A
B
C
D
Illustration 3: LCP Layout
A.
Display area.
B.
Display menu keys for changing the display to show status
options and menu.
C.
Navigation keys for programming functions and moving the
display cursor. Also included are the status indicator lights.
D.
Start/Stop Key.