1.4.
Functional Features
The Washwater Analyzing Unit (WAU) cabinet is equipped with a control panel with a relevant button layout for local
operation. The integrated control panel on the lid of the WAU gives the user access to information about the system and
the measured values for PAH, turbidity and pH.
Among available local control features and information are:
Visual Power ON indication.
Visual Warning indication.
Visual Alarm indication.
Control interface status of the systems operational modes.
Control interface notifications in case of an error or warning.
Menu for setting up the system.
1.5.
Startup
Make sure that both the WAU and the SU are connected with the ship's power grid and that the breaker for WMS systems
power supply is ON.
Illustration 2: illustration of a Breaker for a WMS system
Applying power
When power is applied to the WMS system, the software starts booting. When the display is lit, the WMS is ready for
operation. The system start out in standby mode and the WMS starts measuring after having received a command to do
so.
The startup procedure works in the following way:
The screen is illuminated and an IXA animation starts:
All LEDs are turned on.
When the animation is finished, the LEDs turn off, except On LED and Status LED.
Warning LED will turn on if a warning is active.
Alarm LED will flash if an alarm is active.