Installation Guide Danfoss Link™ CC
25
Danfoss Heating Solutions
VISGL90N
12/2014
GB
Note!
Use pincode [0044] to change between the following regulation types:
Room sensor
(regulates only by room temperature) - if only Danfoss Link™ RS is
fitted (hydronic floor heating) or Danfoss Link™ RS + Danfoss Link™ FT (electrical
heating).
Floor sensor
(regulates only by floor temperature ) - if only Danfoss Link™ FT/S
is fitted.
Combined room/floor
(ensures min. floor temperature and regulates room
temperature in parallel) - Danfoss Link™ RS + Danfoss Link™ FT/S is fitted.
In case of hydronic floor heating, be aware if a certain max. floor temperature is
given by the floor manufacturer. This can be assured by fitting a thermostatically
controlled mixing shunt.