Remote full flow charge pressure filtration, option P for H1P 045/053 S (for endcap option F)
A
A
B
B
C
C
CL
6 ±0.5
60 ±0.8
199.8 ±1.2
177.3 ±1.2
89.5 ±0.8
Shaft
Charge inlet port "S"
Port ISO 11926-1 - 1 5/16-12
93.5 ±0.8
Charge filtr
ation por
t "E"
Port ISO 11926-1 - 7/8-14
From filt
er
(199.8)
15°
Charge filtr
ation por
t "F"
Port ISO 11926-1 - 7/8-14
To filter
(199.8)
93.5 ±0.8
15°
P700 33 360
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Filtration
©
Danfoss | May 2017
11063344 | BC00000059en-US1001 | 63