A
G
H
J
K
M
N
S T
V
W
X
Y
Z
D
E
F
A
H1P
A B
F – Orifices
Code
Orifice
Controls: To be used for ( ) / NOT to be used for (–)
Tank (A+B)
P
A / B
EDC, FNR
MDC
NFPE, AC
FDC
C3
No orifice
–
–
C1
–
–
0.8 mm
–
C2
–
–
1.3 mm
C4
–
–
1.8 mm
–
C6
1.0 mm
–
–
–
–
C7
1.3 mm
–
–
–
–
–
C8
0.6 mm
0.8 mm
–
–
–
–
C9
0.6 mm
1.0 mm
–
–
–
–
D1
0.8 mm
1.0 mm
–
–
–
–
D2
0.8 mm
1.3 mm
–
–
–
–
D3
1.0 mm
1.3 mm
–
–
–
–
D4
1.0 mm
1.3 mm
1.3 mm
–
–
–
D5
0.6 mm
0.6 mm
0.8 mm
–
–
–
D8
–
–
2.3 mm
–
–
–
E – Displacement limiter
N
None
C
No limiters, with nested springs, required for NFPE, AC, FDC
*
B
Adjustable externally
D
Adjustable externally with nested springs, required for NFPE, AC, FDC
*
Align with option
Y: Settings for adjustment (if applicable).ima1444887758105
Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Master Model Code
12 |
©
Danfoss | May 2017
11063344 | BC00000059en-US1001