Swash plate angle sensor for NFPE and AC2 controls
The angle sensor detects the swash plate angle position and direction of rotation from the zero position.
The swash angle sensor works on the AMR sensing technology. Under the saturated magnetic field, the
resistance of the element varies with the magnetic field direction. The output signal give a linear output
voltage for the various magnet positions in the sensing range. The swashplate angle sensor is available
for all NFPE and AC2 controls.
P301 750
-25°
-20°
-15°
-10°
-5°
0°
5°
10°
15°
20°
25°
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
0
Swashplate angle
O
utput v
oltage (
V
)
P005 704E
Signal 1 (nominal)
Signal 2 (redundant)
Swashplate angle vs. output voltage (calibrated at 50 °C)
Swash Plate Angle Sensor Parameters
Parameter
Minimum
Typical
Maximum
Supply voltage range
4.75 V
5 V
5.25 V
Supply protection
–
–
28 V
Supply current
–
22 mA
25 mA
Output current (Signal 1, 2)
–
0.1 mA
–
Short circuit output current to supply or GND
1)
–
–
7.5 mA
Sensitivity
70.0 mV/deg
78.0 mV/deg
85.8 mV/deg
Working range (swashplate angle)
–18°C
0°C
18°C
Correlation between signals 1 and 2
2)
475 mV
500 mV
525 mV
1)
Up to duration of 2.5 seconds at 25°C
2)
Signal 1 (nominal) is lower than signal 2 (redundant)
Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Control Options
34 |
©
Danfoss | May 2017
11063344 | BC00000059en-US1001