Automotive Control (AC) Dimensions
61.2 ±0.8
61.2 ±0.8
30.2 ±0.8
AA
AB
2x A
C
C1
CAN
CC2
CC2
C2
V
209 max
AD
V
P005 930
4
3
1
2
CAN
CC1
CC2
CCC3
220 ±2.5
110 ±1.5
1. Mounting flange
2. Shaft
3. Plug removing can cause contamination issues
4. PPU wire harness is factory installed to speed sensor
Dimensions, (mm)
Callout
Value
AA
208.9 ±2.5
AB
190.5 ±1.2
AC
2x 187.1 ±1.2
AD
89.2 ±1.2
Connectors description
Port
Description
C1
C2
Control MOR;
Depressing the plunger mechanically moves the control spool. Actuation allows full stroke
pump response as per coil and rotation dependent control logic.
CC1
Control connector Deutsch DTM04-12P -A; Paint free
CC2
Control connector Deutsch DTM04-12P -B; Paint free
CCC3
Control connector Deutsch DT06-2S; Paint free; For using connector the plug may be
removed.
CAN
Control connector Deutsch DTM04-3P; Paint free; For using connector the plug may be
removed.
Please contact Danfoss representative for specific installation drawings.
Technical Information
H1 Axial Piston Single Pumps, Size 045/053
Controls
60 |
©
Danfoss | May 2017
11063344 | BC00000059en-US1001