FCM 300 Series
MG.03.B6.2G - VLT is a registered Danfoss trademark
LCP-2
Remote Mounting Kit continued....
Local Operation Pad (LOP)
The LOP is wired directly to the X101 control
terminals. The LOP provides speed control, a start/
stop function and, depending on how it is wired and
programmed, the following three functions:
1. Dual speed operation
2. Dual mode operation (Uses 2-Set-up Menus)
3. Dual direction operation (For forward or reverse)
Color of wire
Color of wire
Color of wire
Color of wire
Color of wire
T
T
T
T
Terminal
erminal
erminal
erminal
erminal
Function
Function
Function
Function
Function
White
2
Reference
Brown
3
Reset
Orange or Gray
4
See table under button
Green
5
See table under button
Red
6
+24V
Yellow
7
+10V
Blue
8
Ground
W
W
W
W
W iring
iring
iring
iring
iring
Function/settings
Function/settings
Function/settings
Function/settings
Function/settings
Key (Start)
Key (Start)
Key (Start)
Key (Start)
Key (Start)
Key (Start)
Key (Start)
Key (Start)
Key (Start)
Key (Start)
Key (Stop)
Key (Stop)
Key (Stop)
Key (Stop)
Key (Stop)
Default - Dual speed operation
Default - Dual speed operation
Default - Dual speed operation
Default - Dual speed operation
Default - Dual speed operation
Run on set
Run on
Stop (and
(connect orange wire):
(connect orange wire):
(connect orange wire):
(connect orange wire):
(connect orange wire):
reference
10 Hz**
reset* - if trip)
No changes to factory setting.
(+/-)
jog speed
Function 2 - Dual mode operation
Function 2 - Dual mode operation
Function 2 - Dual mode operation
Function 2 - Dual mode operation
Function 2 - Dual mode operation
(connect orange wire):
(connect orange wire):
(connect orange wire):
(connect orange wire):
(connect orange wire):
Run with
Run with
Stop (and
Select desired modes of operation
Setup 1
Setup 2
reset* - if trip)
in Setups 1 and 2 (use para. 4-6)
Parameter 335 = 18 (select Setup)
Function 3 - Dual direction operation
Function 3 - Dual direction operation
Function 3 - Dual direction operation
Function 3 - Dual direction operation
Function 3 - Dual direction operation
(connect grey wire):
(connect grey wire):
(connect grey wire):
(connect grey wire):
(connect grey wire):
Run
Run
Stop (and
Parameter 335 = 10 (start reversing)
forward
reverse
reset* - if trip)
Parameter 200 = 1 (both directions)
*If no reset is required,
**or set parameter 213
do not connect the brown wire
At power up the unit will always be in stop mode.
Set reference will be stored during power down. If
permanent start mode is desired, connect terminal
6 to terminal 4 and do not connect orange/gray
wire to terminal 4. This means the stop function on
LOP is disabled.
NOTE!
After wiring the LOP, cut off or isolate any
excess wire.
■
■
Operation
7-4
Содержание FCM305 56
Страница 4: ......
Страница 8: ...FCM 300 Series MG 03 B6 2G VLT is a registered Danfoss trademark...
Страница 16: ......
Страница 24: ......
Страница 46: ......
Страница 60: ......
Страница 74: ......
Страница 94: ......
Страница 110: ......
Страница 126: ......
Страница 131: ......
Страница 132: ......