FCM 300 Series
MG.03.B6.2G - VLT is a registered Danfoss trademark
✭
=
General factory setting - also applying to spare part unit, H
H
H
H
H = HVAC setting, IIIII = Industrial setting,
( ) = display text [ ] = value for use in communication via serial communication port
Parameter Group 0: Operation & Display
DC link voltage [V] (DC LINK VOLTAGE [V])
[12]
Thermal load, FC [%] (FC THERMAL [%])
[14]
Hours run [Hours] (RUNNING HOURS)
[15]
Digital input [Binary code] (DIGITAL INPUT [BIN])
[16]
External reference [%] (EXTERNAL REF [%])
[21]
Status word [Hex] (STATUS WORD [HEX])
[22]
Heat sink temp. [°C] (HEATSINK TEMP [°C])
[25]
Alarm word [Hex] (ALARM WORD [HEX])
[26]
Control word [Hex] (CONTROL WORD [HEX])
[27]
Warning word 1 [Hex]
(WARNING WORD 1 [HEX])
[28]
Warning word 2 [Hex]
(WARNING WORD 2 [HEX])
[29]
Analog input 1 [mA] (ANALOG INPUT 1 [mA])
[30]
Analog input 2 [V] (ANALOG INPUT 2 [V])
[31]
Function:
This parameter allows a choice of the data value to
be displayed in line 2 of the display.
Parameters 010-012 enable the use of three
additional data values to be displayed in line 1.
NOTE!
In parameter 009, "none" [0] cannot be selected.
Description of choice:
Reference
Reference
Reference
Reference
Reference
[%]
[%]
[%]
[%]
[%] corresponds to the total reference
(sum of digital/analog/preset/bus/freeze ref./catch-
up and slow-down).
Reference
Reference
Reference
Reference
Reference
[unit]
[unit]
[unit]
[unit]
[unit] gives the sum of the references
using the unit stated on the basis of configuration in
parameter 100 (Hz, Hz and rpm).
Feedback
Feedback
Feedback
Feedback
Feedback
[unit]
[unit]
[unit]
[unit]
[unit] gives the status value of terminal 1
and 2 using the unit/scale selected in parameter
414, 415 and 416.
Frequency
Frequency
Frequency
Frequency
Frequency
[Hz]
[Hz]
[Hz]
[Hz]
[Hz] gives the motor frequency, i.e. the
output frequency to the motor.
Frequency x Scaling
Frequency x Scaling
Frequency x Scaling
Frequency x Scaling
Frequency x Scaling
[-]
[-]
[-]
[-]
[-] corresponds to the present
motor frequency f
M
multiplied by a factor (scaling) set
in parameter 008.
Motor current
Motor current
Motor current
Motor current
Motor current
[A]
[A]
[A]
[A]
[A] states the phase current of the
motor measured as effective value.
T
T
T
T
Torque
orque
orque
orque
orque
[%]
[%]
[%]
[%]
[%] gives the current motor load in relation
to the rated motor torque.
Power
Power
Power
Power
Power
[kW]
[kW]
[kW]
[kW]
[kW] states the actual power consumed by
the motor in kW.
Power
Power
Power
Power
Power
[HP]
[HP]
[HP]
[HP]
[HP] states the actual power consumed by
the motor in HP.
Motor voltage
Motor voltage
Motor voltage
Motor voltage
Motor voltage
[V]
[V]
[V]
[V]
[V] states the voltage supplied to the
motor.
DC link voltage
DC link voltage
DC link voltage
DC link voltage
DC link voltage
[V]
[V]
[V]
[V]
[V] states the intermediate circuit
voltage in the FCM 300.
Thermal load, FC
Thermal load, FC
Thermal load, FC
Thermal load, FC
Thermal load, FC
[%]
[%]
[%]
[%]
[%] states the calculated/
estimated thermal load on the FCM 300. 100% is
the cut-out limit.
Hours run
Hours run
Hours run
Hours run
Hours run
[Hours]
[Hours]
[Hours]
[Hours]
[Hours] states the number of hours that
the motor has run since the latest reset in
parameter 619.
Digital input
Digital input
Digital input
Digital input
Digital input
[Binary code]
[Binary code]
[Binary code]
[Binary code]
[Binary code] states the signal states
from the 4 digital terminals (2, 3, 4 and 5). Input 5
corresponds to the bit at the far left. '0' = no signal,
'1' = connected signal.
External reference
External reference
External reference
External reference
External reference
[%]
[%]
[%]
[%]
[%] gives the sum of the external
reference as a percentage (the sum of analog/pulse/
bus).
Status word
Status word
Status word
Status word
Status word
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] gives the status word sent via
the serial communication port in Hex code from the
FCM 300.
Heat sink
Heat sink
Heat sink
Heat sink
Heat sink temp.
temp.
temp.
temp.
temp.
[°C]
[°C]
[°C]
[°C]
[°C] states the present heat sink
temperature of the FCM 300. The cut-out limit is 90 ±
5°C; cutting back in occurs at 60 ± 5°C.
Alarm word
Alarm word
Alarm word
Alarm word
Alarm word
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates one or several alarms in
a Hex code.
Control word.
Control word.
Control word.
Control word.
Control word.
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates the control word for
the FC motor. See
Serial communication
.
Warning word 1.
Warning word 1.
Warning word 1.
Warning word 1.
Warning word 1.
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates one or more
warnings in a Hex code.
Warning word 2.
Warning word 2.
Warning word 2.
Warning word 2.
Warning word 2.
[Hex]
[Hex]
[Hex]
[Hex]
[Hex] indicates one or more
status states in a Hex code.
Analog input 1 [mA]
Analog input 1 [mA]
Analog input 1 [mA]
Analog input 1 [mA]
Analog input 1 [mA]
, states the signal value on
terminal 1.
Analog input 2 [V]
Analog input 2 [V]
Analog input 2 [V]
Analog input 2 [V]
Analog input 2 [V]
, states the signal value on
terminal 2.
010 Display line 1.1 (DISPLAY LINE 1.1)
Value:
✭
Reference [%]
[1]
See parameter 009.
Function:
This parameter enables a choice of the first of three
data values to be shown on the display, line 1,
position 1.
For display read-outs, press the [DISPLAY/STATUS]
button.
8-5
Содержание FCM305 56
Страница 4: ......
Страница 8: ...FCM 300 Series MG 03 B6 2G VLT is a registered Danfoss trademark...
Страница 16: ......
Страница 24: ......
Страница 46: ......
Страница 60: ......
Страница 74: ......
Страница 94: ......
Страница 110: ......
Страница 126: ......
Страница 131: ......
Страница 132: ......