FC 300 Instruction Manual
How to Program
"
10-** CAN fieldbus
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
10-0* Common settings
10-00 CAN protocol
[1] Device Net
All set-ups
FALSE
-
Uint8
10-01 Baudrate select
[20] 125 Kbps
All set-ups
FALSE
-
Uint8
10-02 MAC ID
63
All set-ups
FALSE
0
Uint8
10-05 Readout Transmit Error Counter
0
All set-ups
TRUE
0
Uint8
10-06 Readout Receive Error Counter
0
All set-ups
TRUE
0
Uint8
10-07 Readout Bus Off Counter
0
All set-ups
TRUE
0
Uint16
10-1* DeviceNet
10-10 Process data type selection
App. dependent
1 set-up
TRUE
-
Uint8
10-11 Process Data Config Write
0
All set-ups
FALSE
0
Uint8
10-12 Process Data Config Read
0
All set-ups
FALSE
0
Uint8
10-13 Warning Parameter
63
All set-ups
FALSE
0
Uint8
10-14 Net Reference
[0] Off
All set-ups
TRUE
-
Uint8
10-15 Net Control
[0] Off
All set-ups
TRUE
-
Uint8
10-2* COS filters
10-20 COS Filter 1
65535
All set-ups
FALSE
0
Uint16
10-21 COS Filter 2
65535
All set-ups
FALSE
0
Uint16
10-22 COS Filter 3
65535
All set-ups
FALSE
0
Uint16
10-23 COS Filter 4
65535
All set-ups
FALSE
0
Uint16
10-3* Parameter access
10-30 Parameter Data Types
[0] Errata 1
All set-ups
TRUE
-
Uint8
10-31 Array index
0
All set-ups
TRUE
0
Uint16
10-39 Devicenet F parameters
0
All set-ups
TRUE
0
Uint32
"
13-** Smart logic control
Par.
No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
13-1* Comparators
13-10 Comparator Operand
[0] DISABLED
2 set-ups
FALSE
-
Uint8
13-11 Comparator Operator
[1]
≈
2 set-ups
FALSE
-
Uint8
13-12 Comparator Value
0.000
2 set-ups
FALSE
-3
Int32
13-2* Timers
13-20 SL control timer
0.000 s
1 set-up
FALSE
-3
TimD
13-4* Logic rules
13-40 Logic Rule Boolean 1
[0] False
2 set-ups
FALSE
-
Uint8
13-41 Logic Rule Operator 1
[0] DISABLED
2 set-ups
FALSE
-
Uint8
13-42 Logic Rule Boolean 2
[0] False
2 set-ups
FALSE
-
Uint8
13-43 Logic Rule Operator 2
[0] DISABLED
2 set-ups
FALSE
-
Uint8
13-44 Logic Rule Boolean 3
[0] False
2 set-ups
FALSE
-
Uint8
13-5* Smart logic ctrl.
13-50 SL control mode
[0] Off
2 set-ups
FALSE
-
Uint8
13-51 SL control event
[0] False
2 set-ups
FALSE
-
Uint8
13-52 SL control action
[0] DISABLED
2 set-ups
FALSE
-
Uint8
*
default setting
( )
display text
[ ]
value for use in communication via serial communication port
55
MG.33.A4.22 - VLT is a registered Danfoss trademark
Содержание FC 302
Страница 34: ...FC 300 Instruction Manual How to Install 34 MG 33 A4 22 VLT is a registered Danfoss trademark...
Страница 74: ...FC 300 Instruction Manual Troubleshooting 74 MG 33 A4 22 VLT is a registered Danfoss trademark...
Страница 77: ...FC 300 Instruction Manual Index 4 485 V DC 63 77 MG 33 A4 22 VLT is a registered Danfoss trademark...