P15K
P18K
P22K
P30K
P37K
High/Normal Load
1)
HO
NO
HO
NO
HO
NO
HO
NO
HO
NO
Typical Shaft Output [kW]
15
18.5
18.5
22
22
30
30
37
37
45
Enclosure IP20
B4
C3
C3
C4
C4
Enclosure IP21
C1
C1
C1
C2
C2
Enclosure IP55, IP66
C1
C1
C1
C2
C2
Output current
Continuous (3x200-240 V) [A]
59.4
74.8
74.8
88
88
115
115
143
143
170
Intermittent
(60 s overload)
(3x200-240 V) [A]
89.1
82.3
112
96.8
132
127
173
157
215
187
Continuous kVA (208 V AC) [kVA]
21.4
26.9
26.9
31.7
31.7
41.4
41.4
51.5
51.5
61.2
Max. input current
Continuous (3x200-240 V) [A]
54
68
68
80
80
104
104
130
130
154
Intermittent
(60 s overload)
(3x200-240 V) [A]
81
74.8
102
88
120
114
156
143
195
169
Additional specifications
IP20 max. cable cross-section
5)
(mains, brake, motor and load
sharing)
35 (2)
50 (1)
50 (1)
150 (300MCM)
150 (300MCM)
IP21, IP55, IP66 max. cable cross-
section
5)
(mains, motor) [mm
2
(AWG)]
2)
50 (1)
50 (1)
50 (1)
150 (300MCM)
150 (300MCM)
IP21, IP55, IP66 max. cable cross-
section
5)
(brake, load sharing)
[mm
2
(AWG)]
2)
50 (1)
50 (1)
50 (1)
95 (3/0)
95 (3/0)
Max cable size with mains
disconnect [mm
2
(AWG)]
2)
50, 35, 35 (1, 2, 2)
95, 70, 70
(3/0, 2/0, 2/0)
185, 150, 120
(350MCM,
300MCM, 4/0)
Estimated power loss
at rated max. load [W]
4)
624
737
740
845
874
1140
1143
1353
1400
1636
Weight, enclosure IP21, IP55/IP66
[kg]
45
45
45
65
65
Efficiency
4)
0.96
0.97
0.97
0.97
0.97
Table 10.3 Mains Supply 3x200-240 V AC
For fuse ratings, see 10.3.1 Fuses
1) High overload = 160% torque during 60 s. Normal overload = 110% torque during 60 s.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within
±
15% (tolerence relates to variety in voltage and
cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the
frequency converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to 30 W to the losses.
(Though typical only 4 W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (
±
5%).
5) The three values for the max. cable cross section are for single core, flexible wire and flexible wire with sleeve, respectively.
Specifications
VLT
®
AutomationDrive Operating
Instructions
66
MG33AM02 - VLT
®
is a registered Danfoss trademark
10
10
Содержание FC 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions VLT AutomationDrive FC 300 0 25 75 kW...
Страница 2: ......
Страница 4: ...Safety VLT AutomationDrive Operating Instructions MG33AM02 VLT is a registered Danfoss trademark...
Страница 99: ...Index VLT AutomationDrive Operating Instructions MG33AM02 VLT is a registered Danfoss trademark 95...
Страница 100: ...www danfoss com drives MG33AM02 130R0300 MG33AM02 Rev 2012 11 02...