1.
Connect the voltage selection plug to the correct slot in the con-
trol cabinet -
Δ 230 V on connection (3), Υ 400 V on connection
(1).
2.
Set the motor protection switch (2) as specified in the Technical
data.
The permissible voltage frequency ranges and the relevant motor
protection setting are also indicated on the sticker in the control
cabinet door.
3.
Have the power cable of the machine connected to the local
mains by a qualified electrician according to the regulations of
the Electricity Board.
4.
Check the electric motor rotational direction according to the ar-
row. Exchange outer cable (phases) of the connection, if requi-
red.