1.
Connect the voltage selection plug to the correct slot in the con-
trol cabinet -
Δ 230 V on connection (3), Υ 400 V on connection
(2).
2.
Set the motor protection switch (1) as specified in Section 3,
“Technical data”.
The permissible voltage frequency ranges and the relevant motor
protection setting are also indicated on the sticker in the control ca-
binet door.
3.
Have the power cable of the machine connected to the local
mains by a qualified electrician according to the regulations of
the Electricity Board.