Table 8. Pin con guration of the Deutch HD34-24-47PE connector
Measurement
Description
PIN
Temperature 1
Temperature 1, PT100 (P), windings
47
Temperature 1, PT100 (N), windings
46
Temperature 2
Temperature 2, PT100 (P), windings
33
Temperature 2, PT100 (N), windings
32
Temperature 3
Temperature 3, PT100 (P), windings
45
Temperature 3, PT100 (N), windings
31
Temperature 4
Temperature 4, PT100 (P), windings
30
Temperature 4, PT100 (N), windings
29
Temperature 5
Temperature 5, PT100 (P), windings
44
Temperature 5, PT100 (N), windings
43
Temperature 6
Temperature 6, PT100 (P), windings
28
Temperature 6, PT100 (N), windings
16
Temperature 7
Temperature 7, PT100 (P), windings, option TEMP4
42
Temperature 7, PT100 (N), windings, option TEMP4
27
Temperature 8
Temperature 8, PT100 (P), windings, option TEMP4
15
Temperature 8, PT100 (N), windings, option TEMP4
14
Temperature 9
Temperature 9, PT100 (P), windings, option TEMP4
40
Temperature 9, PT100 (N), windings, option TEMP4
26
Temperature 10
Temperature 10, PT100 (P), windings, option TEMP4
41
Temperature 10, PT100 (N), windings, option TEMP4
13
Temperature 11
Temperature 11, PT100 (P), windings, option TEMP4
39
Temperature 11, PT100 (N), windings, option TEMP4
38
Temperature 12
Temperature 12, PT100 (P), windings, option TEMP4
25
Temperature 12, PT100 (N), windings, option TEMP4
12
Resolver COS_N
Resolver, RES_COS_N, in-built non contacting
35
Resolver COS_P
Resolver, RES_COS_P, in-built non contacting
20
Resolver SIN_N
Resolver, RES_SIN_N , in-built non contacting
36
Resolver SIN_P
Resolver, RES_SIN_P , in-built non contacting
21
Resolver EXCN
Resolver, EXCN, in-built non contacting
22
Resolver EXCP
Resolver, EXCP, in-built non contacting
10
Resolver shield
Resolver, SHIELD/GROUND, in-built non contacting
34
EM-PMI540-T3000
6. Installation
38 |
©
Danfoss | Produced By: Danfoss Power Solutions | November 2018
| BC265857716810en-000103