4 – Installation instructions
VMIFJ102
2
Important information
Caution! The heat pump must be located in a frost-free environment!
Caution! The installation may only be commissioned if the heating system is filled and bled. Otherwise
the circulation pump can be damaged.
Caution! If the electrician wishes to test his connections before the above is carried out, this should only
done when it has been checked that the heat pump, the electric boiler, the compressor and the heat
shields are disconnected.
Caution! When filling the coolant system the coolant pump must be operating but one must ensure that
the compressor and the heat transfer pump cannot start.
The system can be considered maintenance free but certain checks are necessary.
Before changing the control computer’s settings, first find out what these changes mean.
Contact your installer for any service work.
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Cleaning and user maintenance shall not be made by children without supervision.
Note! Children are not permitted to play with the apparatus.
2.1
Refrigerant
The heat pump’s cooling system (refrigerant circuit) is filled with R4
10A
refrigerant.
Caution! Work on the refrigerant circuit must only be carried out by a certified engineer!
Caution! Fire risk R4
10A
is not combustible or explosive in normal conditions.
Toxicity
In normal use and normal conditions the refrigerant has low toxicity. However, although the toxicity of the refrig‐
erant is low, it can cause injury (or be highly dangerous) in abnormal circumstances or where deliberately abused.
The refrigerant vapour is many times heavier than air and in enclosed spaces, below the level of the door for
example, and in the event of leakage, large concentrations can occur with the risk of suffocation because of lack
of oxygen. Spaces in which heavy vapour can collect below the level of the air must therefore be well ventilated.
Note! This appliance is intended to be used by expert or trained users in shops, in light industry and on
farms or commercial use by lay persons.
Only spare parts approved by us may be used in this appliance.
Caution!
The power supply must be disconnected during service and before changing parts in the
appliance.