11.1.3
Sub menu AUX. HEATER
Table 10.
Used to change the heat pump stages’ operating settings.
Menu selection
Meaning
Factory setting
MAX STEP
Maximum number of permitted steps for auxiliary heating.
= no auxiliary heating permitted (Means that only AUTO,
HEAT PUMP or [SYMBOL] can be selected and that no anti-
legionella operation is possible.)
(range:
, 1
INTEGRAL A2
Two conditions must be fulfilled in order to start the auxiliary
heater: the integral’s value to start must be less than integral
A1 + A2, and the supply temperature must be 2°C lower than
the calculated temperature. See Important parameters for fur-
ther information.
-600
(range: -50 / -990)
HYSTERESIS
If the difference between the actual supply temperature and
the calculated supply temperature is too great (see Important
parameters), either the integral value is set to start value A1 +
A2 (starts the auxiliary heater) or to 0 (stops the auxiliary
heater ).
20°C
(range: 5°C / 30°C)
DELAY AFTER EVU
Time in minutes. Indicates how many minutes after EVU are to
pass before the auxiliary heater may be activated.
30M
(range: 0M / 120M
Max Current
(Expansion card)
Refers to main fuse in the unit, in amperes
20
(range: 16 / 35)
HOT WATER STOP
Stop temperature for hot water during AUX. HEATER. The value
is read off by the hot water sensor.
60°C
(range: 50°C / 65°C)
EXT.AUX.HEATER
Menu selection
Meaning
EXT.AUX.HEATER
Switch the
external auxil-
iary heater off
and on.
OFF / ON
INTEGRAL A3
Indicates the
value of the
integral when
external auxil-
iary heater is
connected.
-300
(range: -990 / INTEGRAL
A1 - 10)
TURN OFF DELAY
Indicates how
long the
external auxil-
iary heater
must con-
tinue to be
active after its
demand is no
longer nee-
ded.
0M
(range: 0M / 180M)
32 – Installation instructions
VMIFJ102