Start up
During and immediately after the pump start up, any hydraulic system must be closely and frequently

checked.

1. To assure best pump performance, run the pump for approximately one hour at 30% of rated

pressure and speed before running at full load.
When running make sure the pump and oil temperature and noise level are sufficiently low. High

temperature or noise level might be symptoms of unforeseen operation conditions that have to be

analyzed and cleared.

2. Check for system leakage and make sure the system is operating satisfactorily.
3. To ensure that the contamination in the hydraulic system does not damage the pump; the following

procedure is recommended after a brief period in operation:

a) After a brief period in operation, have a hydraulic fluid specimen analyzed for the required

cleanliness level.

b) Replace oil filter or change the hydraulic fluid if the required cleanliness level is not reached.

Operational checks

The product is a component which requires no settings or changes during operation.

The machine/system manufacturer is responsible for the proper project planning of the hydraulic system
and its control.

Danfoss recommends ongoing tests for optimal pump performance.

1. Regularly verify that the temperature of the ambient and the operating oil are those initially

determined.

2. Do not subject the pump to pressure, pressure drop or speeds exceeding the maximum values stated

in the appropriate catalogs.

3. Filter the oil to maintain the grade of contamination at 22/20/16 (ISO 4406-1999) or better.

Maintenance

W

Warning

If maintenance has to be performed in an explosive and hazardous atmosphere, an anti-sparking safety

tool must be used.

User Manual

ATEX certified D1P 130/145/193/260

Installation, operation and maintenance

 

12 | 

©

 Danfoss | August 2021

BC376161003883en-000101

Содержание D1P130

Страница 1: ...User Manual ATEX certified Axial piston pump variable displacement D1P130 D1P145 193 260 www danfoss com...

Страница 2: ...Revision history Table of revisions Date Changed Rev August 2021 First edition 0101 User Manual ATEX certified D1P 130 145 193 260 2 Danfoss August 2021 BC376161003883en 000101...

Страница 3: ...ting fluids 7 Viscosity and temperature for D1P pump 8 Ambient temperature 8 Oil temperature 8 Viscosity 8 Filtering 9 Installation operation and maintenance Assembly of D1 pump to the system 10 Opera...

Страница 4: ...afety The safety of the product depends upon the strict observation of the indications given in this User Manual in particular it is necessary to Always operate within allowed product working operatin...

Страница 5: ...Ex II 3G Ex h IIA T3 Gc AN3 temperature class T3 CE Ex II 3G Ex h IIA T4 Gc AN4 temperature class T4 CE Ex II 3G Ex h IIA T5 Gc AN5 temperature class T5 See Viscosity and temperature for D1P pump on p...

Страница 6: ...ly explosive atmospheres With following parameters Equipment group II Zone 2 gas Equipment Category 3G Temperature class T5 T3 Explosion protection group II A The Conformity Assessment Procedure has t...

Страница 7: ...40 F T5 T4 T4 80 C 176 F T4 T4 T3 115 C 239 F T3 T3 T3 T codes maximum surface temperature Temperature class Maximum surface temperature C F T3 200 392 T4 135 275 T5 100 212 To ensure that the surface...

Страница 8: ...account by the safety margin to the minimum ignition temperature of the dust concerned For up to 5 mm 1 97 in layer thickness the safety margin is 75 C 167 F For further information please see IEC 600...

Страница 9: ...t the actual operating temperature Filtering It is necessary to keep the level of oil contamination at an acceptable level to ensure problem free operation The recommended maximum level of contaminati...

Страница 10: ...200 C for Group 11G Make sure that all type of accessory installed on the pump are ATEX specified and have been installed in accordance with ATEX requirements There are no creeping metal elements exte...

Страница 11: ...shaft with inlet pressure in the rear port Generic illustration shown 3 Select the hydraulic fluid as specified in Oil types Operating fluids 4 Ensure full contact between pump mounting flange and con...

Страница 12: ...eanliness level b Replace oil filter or change the hydraulic fluid if the required cleanliness level is not reached Operational checks The product is a component which requires no settings or changes...

Страница 13: ...color bad smell acidity increase and because of the generation of sludge inside the tank In case symptoms of this kind are detected the system oil must be immediately changed Water presence The prese...

Страница 14: ...ause injury to the technician or bystanders To protect against unintended movement secure the machine or disable disconnect the mechanism while servicing Follow the manufacturers instructions for secu...

Страница 15: ...nfoss Power Solutions US Company 2800 East 13th Street Ames IA 50010 USA Phone 1 515 239 6000 Danfoss Power Solutions Trading Shanghai Co Ltd Building 22 No 1000 Jin Hai Rd Jin Qiao Pudong New Distric...

Отзывы: