Webpage
Lyra Digital Mixer from D&R Phone +31 294 418014, email:
Page 40
11.5 Global Settings
In the global setting screen you can make all kinds of basic settings.
Figure 27: Global Settings
Clock Source
Clock source lets you choose the clock to which you want to synchronize the
Lyra. You can choose the following sources.
- 32
kHz
internal
- 44.1
kHz
internal
- 48
kHz
internal
- Extern
- 48
kHz
Cobranet
The clock frequency chosen is also the clock which is on the Word-clock OUT.
Note:
If you are using Cobranet you have to select 48 kHz Cobranet
clock. If not the Cobranet input selections menu options will be
disabled.
Digital Nominal Level Lets you adjust the headroom for the digital outputs. See also chapter 6.
Auto CUE Reset
This option resets the CUE when a channel goes on air. When this option is
enabled you need to set per channel if you want a local or a total CUE reset.
CUE to CRM
When this option is set the CUE buss will automatically be routed to the CRM
buss when the CUE is activated on a channel.
CRM interlock
If this option is enabled you can only route one buss at a time to the CRM
buss.
CRM Dim
You can set the amount of dimming you want on the CRM buss when pressing
the DIM button one the Control-surface. (0 to -144dB)
CUE to CRM Dim
When activating a CUE when CUE to CRM is active, the signal level on the
CRM buss will be dimmed by the specified value (0 to -144dB).
EQ Range
The EQ range indicates the range that the three EQ levels can be adjusted. (0
to 18dB)
Aux Pre
Determines if Aux signal is retrieved pre-fader or post-fader.