74
Service Codes
TT10: Internal HVIL connection fault
HVIL
The HVIL is short for “High Voltage Interlock Loop”.
HVIL is a hardware signal, and its purpose is to
protect the user. When the system is fully installed
and connected, the HVIL internal loop is closed which
results in a short circuit between its two input pins.
The HVIL signal is used to open the high-voltage
battery contactor when its internal loop is opened
during product maintenance or repair (e.g. removal of
MCU cover or disconnection of motor sensor cable)
thereby protecting the user.
Description
The Troubleshooting Tree 10 indicates that the HVIL
lines have an internal fault. The possible causes of
this error are listed below, in order of likelihood:
1.
The HVIL parameters were not configured
correctly. The user must access the parameters
through TM4 ODIN and set them.
2.
The MCU phase cables, sensor cables, or DC
input cables are not inserted properly. The
system must be turned OFF before the cables
can be inserted and locked in again.
3.
The motor sensor cable may not be fully inserted
with connector locking mechanism engaged in
both sides (MCU and motor). The system must
be turned OFF and then the cables must be
locked by the locking mechanism engaged on
both sides (MCU and motor).
4.
The motor is defective.
5.
The MCU is defective.
Note
: Refer to the TM4 Product Operation and
maintenance guide for more details.
Note
: Refer to the TM4 MCU installation guide for
more details on installation and deinstallation
procedure including safety warning considerations
Note
: Refer to the TM4 motor installation guide for
more details on installation and deinstallation
procedure including safety warning considerations
To correctly diagnose the faulty system, connect the
Diagnostic Tool (see «Diagnostics» section for test
equipment
and
descriptions)
and
follow
the
troubleshooting tree procedure below.
See “Safety Warnings” and “Troubleshooting Tips”
sections for general guidelines on system diagnostics.
System Mode
Referred by
SysFile ID
Condition
Possible Causes
Defective
0x031F
The HVIL line
experienced an internal
connection fault.
1.
MCU HVIL parameters were not properly
configured.
2.
MCU phase cables not inserted properly
with locking screws installed.
3.
Motor phase cables not inserted properly
with locking screws installed.
4.
DC input cables not inserted properly with
locking screws installed.
5.
Motor sensor cable not properly inserted
properly.
6.
Defective motor sensor cable.
7.
Defective motor.
8.
Defective MCU.
Содержание TM4 SUMO MD MV
Страница 1: ...1 SUMO MD MV HV Powertrain SUMO MD MV HV Powertrain Troubleshooting Guide March 2021 ...
Страница 37: ...37 Service Codes ...
Страница 39: ...39 Service Codes ...
Страница 42: ...42 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 43: ...43 Service Codes ...
Страница 44: ...44 Service Codes ...
Страница 45: ...45 Service Codes ...
Страница 48: ...48 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 49: ...49 Service Codes ...
Страница 50: ...50 Service Codes ...
Страница 52: ...52 Service Codes Machine internal resistance measurement table ...
Страница 53: ...53 Service Codes Connector Head Identification TM4 Motor connector Type 1 TM4 Motor connector Type 2 ...
Страница 54: ...54 Service Codes ...
Страница 55: ...55 Service Codes ...
Страница 56: ...56 Service Codes ...
Страница 58: ...58 Service Codes ...
Страница 61: ...61 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 62: ...62 Service Codes ...
Страница 63: ...63 Service Codes ...
Страница 66: ...66 Service Codes Connector type 2 pinout ...
Страница 67: ...67 Service Codes ...
Страница 68: ...68 Service Codes ...
Страница 71: ...71 Service Codes Connector type 2 pinout ...
Страница 72: ...72 Service Codes ...
Страница 73: ...73 Service Codes ...
Страница 75: ...75 Service Codes ...
Страница 76: ...76 Service Codes ...
Страница 77: ...77 Service Codes ...
Страница 80: ...80 Service Codes ...
Страница 81: ...81 Service Codes ...
Страница 83: ...83 Service Codes ...
Страница 84: ...84 Service Codes ...
Страница 86: ...86 Service Codes ...
Страница 88: ...88 Service Codes ...
Страница 90: ...90 Service Codes ...
Страница 92: ...92 Service Codes ...
Страница 94: ...94 Service Codes ...
Страница 96: ...96 Service Codes ...
Страница 97: ...97 Service Codes ...
Страница 98: ...98 Service Codes ...
Страница 101: ...101 Service Codes ...
Страница 102: ...102 Service Codes ...
Страница 103: ...103 Service Codes ...
Страница 104: ...104 Service Codes ...
Страница 106: ...106 Service Codes ...
Страница 108: ...108 Service Codes ...
Страница 110: ...110 Service Codes ...
Страница 112: ...112 Service Codes ...
Страница 114: ...114 Service Codes ...
Страница 116: ...116 Service Codes ...
Страница 118: ...118 Service Codes ...
Страница 120: ...120 Service Codes ...
Страница 122: ...122 Service Codes ...
Страница 124: ...124 Service Codes ...
Страница 125: ...125 Service Codes References ...
Страница 128: ...128 Service Codes ...
Страница 129: ...129 Service Codes ...
Страница 130: ...130 Service Codes ...
Страница 131: ...131 Service Codes ...
Страница 132: ...132 Service Codes ...
Страница 134: ...134 Service Codes ...
Страница 135: ...135 Service Codes ...
Страница 136: ...136 Service Codes ...
Страница 137: ...137 Service Codes ...
Страница 138: ...138 Service Codes ...
Страница 141: ...141 Service Codes ...
Страница 142: ...142 Service Codes ...
Страница 144: ...144 Service Codes ...
Страница 146: ...146 Service Codes ...
Страница 148: ...148 Service Codes Connector type 1 and type 2 pinouts Expected resistance measurement between CAN ports ...
Страница 149: ...149 Service Codes ...
Страница 150: ...150 Service Codes ...
Страница 152: ...152 Service Codes ...
Страница 154: ...154 Service Codes ...
Страница 156: ...156 Service Codes ...
Страница 158: ...158 Service Codes ...
Страница 159: ...159 Service Codes ...
Страница 181: ...181 This page intentionally left blank ...