64
Service Codes
TT08: HVIL voltage input fault
HVIL
The HVIL is short for “High Voltage Interlock Loop”.
HVIL is a hardware signal, and its purpose is to
protect the user. When the system is fully installed
and connected, the HVIL internal loop is closed which
results in a short circuit between its two input pins.
The HVIL signal is used to open the high-voltage
battery contactor when its internal loop is opened
during product maintenance or repair (e.g. removal of
MCU cover or disconnection of motor sensor cable)
thereby protecting the user.
Description
The Troubleshooting Tree 08 indicates an error where
the detected voltage for the HVIL loop is outside of the
limits set by the Operations and Maintenance guide.
The potential causes of this SysFile ID are listed
below, in order of likelihood:
1.
The HVIL parameters of the MCU are not set
correctly according the user preferences, and
the Operation and Maintenance guide. The
HVIL parameters should be updated in the
MCU.
2.
There is another system that is opening the
HVIL loop from the HVIL input of the MCU. To
fix this fault refer to the troubleshooting guide
of the other system.
3.
The connectors that connect the HVIL circuit
to the MCU are somehow defective. In this
case, the VMU/ECU connectors must be
disconnected from the MCU and repaired.
4.
The MCU itself is defective. It should be
disconnected and replaced.
Note:
Refer to the TM4 Product installation guide for
more details on installation and deinstallation
procedure including safety warning considerations.
Note:
Refer to the TM4 Product Operation and
maintenance guide for more details.
To correctly diagnose the faulty system, connect the
Diagnostic Tool (see «Diagnostics» section for test
equipment and descriptions) and follow the
troubleshooting tree procedure below.
See “Safety Warnings” and “Troubleshooting Tips”
sections for general guidelines on system diagnostics.
System Mode
Referred by
SysFile ID
Condition
Possible Causes
Defective
0x031D
The HVIL circuit had a
current or voltage that
was outside the limits.
1.
MCU HVIL parameters were not correctly
configured.
2.
Another system opens the HVIL loop from
the HVIL input of the MCU.
3.
Defective VMU/MCU interface connector
on the MCU.
4.
Defective MCU.
Содержание TM4 SUMO MD MV
Страница 1: ...1 SUMO MD MV HV Powertrain SUMO MD MV HV Powertrain Troubleshooting Guide March 2021 ...
Страница 37: ...37 Service Codes ...
Страница 39: ...39 Service Codes ...
Страница 42: ...42 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 43: ...43 Service Codes ...
Страница 44: ...44 Service Codes ...
Страница 45: ...45 Service Codes ...
Страница 48: ...48 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 49: ...49 Service Codes ...
Страница 50: ...50 Service Codes ...
Страница 52: ...52 Service Codes Machine internal resistance measurement table ...
Страница 53: ...53 Service Codes Connector Head Identification TM4 Motor connector Type 1 TM4 Motor connector Type 2 ...
Страница 54: ...54 Service Codes ...
Страница 55: ...55 Service Codes ...
Страница 56: ...56 Service Codes ...
Страница 58: ...58 Service Codes ...
Страница 61: ...61 Service Codes Connector type 2 pinout Connector type 1 pinout ...
Страница 62: ...62 Service Codes ...
Страница 63: ...63 Service Codes ...
Страница 66: ...66 Service Codes Connector type 2 pinout ...
Страница 67: ...67 Service Codes ...
Страница 68: ...68 Service Codes ...
Страница 71: ...71 Service Codes Connector type 2 pinout ...
Страница 72: ...72 Service Codes ...
Страница 73: ...73 Service Codes ...
Страница 75: ...75 Service Codes ...
Страница 76: ...76 Service Codes ...
Страница 77: ...77 Service Codes ...
Страница 80: ...80 Service Codes ...
Страница 81: ...81 Service Codes ...
Страница 83: ...83 Service Codes ...
Страница 84: ...84 Service Codes ...
Страница 86: ...86 Service Codes ...
Страница 88: ...88 Service Codes ...
Страница 90: ...90 Service Codes ...
Страница 92: ...92 Service Codes ...
Страница 94: ...94 Service Codes ...
Страница 96: ...96 Service Codes ...
Страница 97: ...97 Service Codes ...
Страница 98: ...98 Service Codes ...
Страница 101: ...101 Service Codes ...
Страница 102: ...102 Service Codes ...
Страница 103: ...103 Service Codes ...
Страница 104: ...104 Service Codes ...
Страница 106: ...106 Service Codes ...
Страница 108: ...108 Service Codes ...
Страница 110: ...110 Service Codes ...
Страница 112: ...112 Service Codes ...
Страница 114: ...114 Service Codes ...
Страница 116: ...116 Service Codes ...
Страница 118: ...118 Service Codes ...
Страница 120: ...120 Service Codes ...
Страница 122: ...122 Service Codes ...
Страница 124: ...124 Service Codes ...
Страница 125: ...125 Service Codes References ...
Страница 128: ...128 Service Codes ...
Страница 129: ...129 Service Codes ...
Страница 130: ...130 Service Codes ...
Страница 131: ...131 Service Codes ...
Страница 132: ...132 Service Codes ...
Страница 134: ...134 Service Codes ...
Страница 135: ...135 Service Codes ...
Страница 136: ...136 Service Codes ...
Страница 137: ...137 Service Codes ...
Страница 138: ...138 Service Codes ...
Страница 141: ...141 Service Codes ...
Страница 142: ...142 Service Codes ...
Страница 144: ...144 Service Codes ...
Страница 146: ...146 Service Codes ...
Страница 148: ...148 Service Codes Connector type 1 and type 2 pinouts Expected resistance measurement between CAN ports ...
Страница 149: ...149 Service Codes ...
Страница 150: ...150 Service Codes ...
Страница 152: ...152 Service Codes ...
Страница 154: ...154 Service Codes ...
Страница 156: ...156 Service Codes ...
Страница 158: ...158 Service Codes ...
Страница 159: ...159 Service Codes ...
Страница 181: ...181 This page intentionally left blank ...