Configuration Micro-switches
Three sets of 4 switches are used for user configurations not controlled by software. The following figure
is a typical view of each switch set, shown with the individual switch set in the OFF position. Following
the figure, each of the three switch sets is described. Refer to the board component layout for their
positions.
OFF
ON
1
2
3
4
SW1, SW2, SW3 Component View
SW1: General Inputs Signal Switch Point
For each general input, select the threshold voltage detected as a logic high signal. See
"
" on page 90
.
SW1
Switch Number
Assigned to
OFF Position
ON Position
(default)
1
2
3
4
general input 1
general input 2
general input 3
general input 4
Logic Transition at
~2 volts
(preferred for differential
signals)
Logic Transition at
~10 volts
SW2: Trigger Inputs Signal Switch Point
For each trigger input, select the threshold voltage detected as a logic high signal. See
"
" on page 91
.
SW2
Switch Number
Assigned to
OFF Position
(default)
ON Position
1
2
3
4
trigger input 1
trigger input 2
NA
NA
Logic Transition at
~2 volts
(preferred for differential
signals)
Logic Transition at
~10 volts