X64 Xcelera-CL PX4 User's Manual
Appendix: X-I/O Module Option
•
109
Opto-coupled Input: Electrical Details
The two opto-coupled inputs can be used either with TTL or RS422 sources. A simplified input schematic
and important electrical specifications are listed below.
X-I/O Input
GND
Simplified
Opto-coupled
Input
typical 2 places
1
20
2
21
X-I/O Module
Opto-Coupled Input
DB37
Connector
In
In_Opto_1-
In
In_Opto_2-
Input reverse breakdown voltage
5 volts minimum
Maximum average forward input current
25 mA
Maximum input frequency
200 kHz
Maximum Sapera call-back rate
System processing dependent
TTL Input Electrical Details
The six TTL inputs are software configurable (see
"
Configuring User Defined Power-up I/O States
page 110
) for standard TTL logic levels or industrial logic systems (typically 24 volts). The design switch
points are as follows:
•
TTL level mode : trip point at 2V +/- 5%
•
Industrial level mode: trip point at 16V +/- 5%
Содержание X64 Xcelera-CL PX4
Страница 32: ...30 Installing X64 Xcelera CL PX4 X64 Xcelera CL PX4 User s Manual ...
Страница 42: ...40 CamExpert Quick Start X64 Xcelera CL PX4 User s Manual ...
Страница 104: ...102 Camera Link Interface X64 Xcelera CL PX4 User s Manual ...
Страница 124: ...122 Glossary of Terms X64 Xcelera CL PX4 User s Manual ...