74
Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
03-032-20117-01
Teledyne DALSA
Mnemonic
Syntax
Parameters
Description
set ccd d irection
scd
i
Sets the CCD shift d irection w here:
0 =
Forw ard CCD shift d irection.
1 =
Reverse CCD shift d irection.
2 =
Externally controlled d irection control via CC3.
(CC3=1 forw ard , CC3=0 reverse.)
set d igital offset
sdo
t i
Su btracts the inp u t valu e from the vid eo signal p rior to
FPN correction.
t
= tap selection, either
1
or
2
d ep end ing on cam era
m od el, or
0
for all tap s.
i
= Offset in a range from
0
to
2048
DN .
set exp osu re m od e
sem
m
Sets the exp osu re m od e:
2 =
Internal SYN C, internal PRIN , p rogram m able line
rate and exp osu re tim e u sing com m and s
ssf
and
set
3 =
External SYN C, internal PRIN , m axim u m exp osu re
tim e
4
= Sm art EXSYN C
5
= External SYN C and PRIN
6
= External SYN C, internal PRIN , p rogram m able
exp osu re tim e
7 =
Internal p rogram m able SYN C, m axim u m exp osu re
tim e. Factory setting.
8
= Internal SYN C, internal PRIN , p rogram m able
exp osu re tim e. Maxim u m line rate for exp osu re tim e.
set exp osu re tim e
set
f
Sets the exp osu re tim e. Refer to the cam era help screen
(
h
com m and ) for allow able range.
set fp n coeff
sfc
x i
Set the FPN coefficient.
x
=p ixel nu m ber w ithin the range
1
to
sensor pixel
count
.
i
= FPN valu e w ithin the range
0
to
2047
(12-bit LSB).
set inp u t LUT
sil
t i
Set a single valu e in a LUT.
t
=Tap : 1 or 2.
i
=Valu e w ithin the range -255 to +256.
set low er threshold
slt
i
The p ixels below the low er threshold are checked for
and rep orted in the end -of-line sequ ence in a range from
0
-
4095
.
set m irroring m od e
smm
i
0 - 1
set p rnu coeff
spc
x i
Set the PRN U coefficient.
x
=p ixel nu m ber w ithin the range
1
to
sensor pixel
count
.
i
= PRN U valu e w ithin the range
0
to
28671
.
set read ou t m od e
srm
i
Set the read ou t m od e in ord er to clear ou t d ark cu rrent
charge in the vertical transfer gates before the sensor is
read ou t.
0
= Au to.
1
= Dark cu rrent clear.
2
= Im m ed iate read ou t. Does not clear d ark cu rrent.
set su btract backgrou nd
ssb
t i
Su btract the inp u t valu e from the ou tp u t signal.
t
= Tap valu e.
0
for all tap s or
1
to
number of camera taps
for ind ivid u al tap selection.
i
= Su btracted valu e in a range from
0
to
4095
.