64
Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
03-032-20117-01
Teledyne DALSA
Example
w fc 2
Loading a Saved Set of Coefficients
The
lpc
com m and Load s one of the 4 saved sets of p ixel coefficients. In ad d ition, a factory calibrated set
of coefficients is available.
Camera Link Command
Parameter
Description
Notes
lp c i
FPN coefficients set to save.
0
=
Factory calibrated p ixel
coefficients.
1
= Coefficient set one
2
= Coefficient set tw o
3
= Coefficient set three
4
= Coefficient set fou r
Example
lp c 0
Resetting the Current Pixel Coefficients
The
rpc
com m and resets the cu rrent p ixel coefficients to zero. This com m and d oes not reset saved
coefficients.
Camera Link Command
Parameter
Description
Notes
rp c
The d igital offset is not reset.
Example
Rebooting the Camera
The com m and
rc
reboots the cam era. The cam era starts u p w ith the last saved settings and the bau d rate
u sed before the reboot ord er. Previou sly saved p ixel coefficients are also restored .