Spyder3 S3-14 and S3-24 Monochrome Camera User's Manual
43
Teledyne DALSA
03-032-20117-01
Setting the Exposure Time
Sets the cam era’s exp osu re tim e is µs. Cam era m u st be op erating in m od e 2, 6, or 8.
Camera Link Command
Parameter
Description
Notes
set f
Desired exp osu re tim e in µs.
Allow able range is
3
to
3300
µs.*
To read the cu rrent line frequ ency, u se the
com m and
gcp
or
get set
.
If you enter an invalid line rate frequ ency, an
error m essage is retu rned .
*The exp osu re tim e range is based on the
cu rrent line rate.
To d eterm ine the m axim u m exp osu re tim e
allow ed for the cu rrent line rate, u se the
com m and
get ger
.
Example
set 400.5
Baud Rate
Determ ines the sp eed of the serial com m u nication p ort in bp s.
Camera Link Command
Parameter
Description
Notes
sbr m
Bau d rate. Available bau d rates are:
9600
(Defau lt),
19200
,
57600
, and
115200
.
Pow er-on rate is alw ays 9600 bau d .
The rc (reset cam era) com m an d w ill not reset the
cam era to the p ow er-on bau d rate and w ill
reboot u sing the last u sed bau d rate.
Example
sbr 57600